2020
DOI: 10.1016/j.jcsr.2020.105981
|View full text |Cite
|
Sign up to set email alerts
|

Mechanical-property tests on assembled-type light steel modular house

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
10
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
6
2
1

Relationship

2
7

Authors

Journals

citations
Cited by 31 publications
(10 citation statements)
references
References 26 publications
0
10
0
Order By: Relevance
“…However, it can be concluded from the tests on the module-to-module connection in Table 1 that the intra-module beam-to-column connection have a significant influence on the seismic performance of the module-to-module connections, thereby affecting the overall seismic performance of MSC. Zhang et al [ 113 , 114 ] studied the seismic performance of the column-to-corner fitting connection in MSC using cyclic tests and finite element analysis, as shown in Fig. 10 (a).…”
Section: Recent Innovations On the Connectionsmentioning
confidence: 99%
“…However, it can be concluded from the tests on the module-to-module connection in Table 1 that the intra-module beam-to-column connection have a significant influence on the seismic performance of the module-to-module connections, thereby affecting the overall seismic performance of MSC. Zhang et al [ 113 , 114 ] studied the seismic performance of the column-to-corner fitting connection in MSC using cyclic tests and finite element analysis, as shown in Fig. 10 (a).…”
Section: Recent Innovations On the Connectionsmentioning
confidence: 99%
“…Compared to the cold-formed steel buildings, ATLS modular houses have advantages of construction efficiency and removable performance [ 12 14 ]. In contrast to traditional modular structure buildings, the frame and enclosure of the ATLS modular house can be utilized repeatedly [ 15 ].
Fig.
…”
Section: Introductionmentioning
confidence: 99%
“…The structural strength and stability of cold-formed steel lipped channel beam columns under biaxial moments and axial forces were experimentally investigated by Torabian et al [13]. Zhang et al [14] conducted the vertical bearing capacity test of the prefabricated box houses, and the calculation method for the initial rotation stiffness was obtained. Then Zhang et al [15] carried out the test on the full-scale models of prefabricated box houses under longitudinal horizontal load.…”
Section: Introductionmentioning
confidence: 99%