1996
DOI: 10.1109/20.508586
|View full text |Cite
|
Sign up to set email alerts
|

Mechanical performance of a twin-aperture 56 mm bore 1 m long dipole model made with SSC type cables

Abstract: transducers and presents the main results of the measurements. principles, describes the design, fabrication and the calibration of the force acquisition system. This paper reviews the magnet mechanical design magnet quenching were also performed with a high sampling rate excitation. Dynamic measurements of forces and temperatures during stresses and axial forces in the coils during assembly, cooldown and mechanical force transducers based on strain gauges to monitor azimuthal parameters, as well as the final … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

1996
1996
2007
2007

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(1 citation statement)
references
References 2 publications
0
1
0
Order By: Relevance
“…6). This phenomenon, called ratcheting, has been observed in previous magnets [17][18][19][20], and can be related to the friction between the coil and its surrounding components.…”
Section: Strain Gauge Measurementsmentioning
confidence: 81%
“…6). This phenomenon, called ratcheting, has been observed in previous magnets [17][18][19][20], and can be related to the friction between the coil and its surrounding components.…”
Section: Strain Gauge Measurementsmentioning
confidence: 81%