2019
DOI: 10.1049/iet-smt.2018.5096
|View full text |Cite
|
Sign up to set email alerts
|

Measurements on pressboard to understand the effect of solid insulation condition on monitoring of power transformer winding clamping pressure

Abstract: Pressboard is the main building material of a power transformer winding structure. Through-thickness compression behaviour of pressboard has a direct influence on the transformer winding clamping pressure. Being a cellulose based polymeric material with a porous structure, the through-thickness compression behaviour of pressboard is highly non-linear. Also, the mechanical properties of pressboard are moisture, temperature, and ageing status dependent. However, information on the exact behaviour of the through-… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
12
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 19 publications
(12 citation statements)
references
References 22 publications
0
12
0
Order By: Relevance
“…Liao et al [28] have observed that with ageing hydrogen bonds between OIP fibres brake reducing the crystallinity of structure non-linearly, making it brittle. The surface of OIP contains highly hydrophilic hydroxyl groups, which aids the breakage of inter-polymer hydrogen bonds, resulting in loss of mechanical strength [29].…”
Section: Differential Scanning Calorimetrymentioning
confidence: 99%
“…Liao et al [28] have observed that with ageing hydrogen bonds between OIP fibres brake reducing the crystallinity of structure non-linearly, making it brittle. The surface of OIP contains highly hydrophilic hydroxyl groups, which aids the breakage of inter-polymer hydrogen bonds, resulting in loss of mechanical strength [29].…”
Section: Differential Scanning Calorimetrymentioning
confidence: 99%
“…Dissolved gas analysis (DGA) can perform real-time monitoring of the gas composition in the insulating oil [4], and identify whether discharge or high temperature phenomena occur inside the tank, but it is not sensitive to the winding deformation, pressboard misalignment and other faults that do not produce gas. The current studies show that the clamping force reduction will degrade the short-circuit strength of the winding mechanical structure, which is one of the main causes of transformer damages [5,6]. Therefore, a fault diagnosis approach for transformer windings that moves from offline to online is urgently needed.…”
Section: Introductionmentioning
confidence: 99%
“…Earlier, the oil-impregnated CSKP failure was attributed only to electrical and thermal stresses [4]. However, CIGRE identified moisture as a most deleterious agent in the rapid ageing of the CSKP insulation [5,6]. Consequently, moisture, along with thermal and electrical stresses, produces a rapid degradation of the CSKP insulation.…”
Section: Introductionmentioning
confidence: 99%