1992
DOI: 10.1016/0021-9673(92)80076-7
|View full text |Cite
|
Sign up to set email alerts
|

Matrix elimination in ion chromatography by “heart-cut” column-switching techniques

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0
1

Year Published

1994
1994
2014
2014

Publication Types

Select...
6
3

Relationship

0
9

Authors

Journals

citations
Cited by 18 publications
(4 citation statements)
references
References 3 publications
0
3
0
1
Order By: Relevance
“…[15][16][17][18][19] It has universal applicability, does not suffer from the limitations associated with classical matrix elimination in liquid chromatography, and markedly reduces the column abuse that can occur when the capacity of the column has been significantly exceeded. [15][16][17][18][19] It has universal applicability, does not suffer from the limitations associated with classical matrix elimination in liquid chromatography, and markedly reduces the column abuse that can occur when the capacity of the column has been significantly exceeded.…”
Section: Determination Of Bromate In Drinking Water 2237mentioning
confidence: 99%
“…[15][16][17][18][19] It has universal applicability, does not suffer from the limitations associated with classical matrix elimination in liquid chromatography, and markedly reduces the column abuse that can occur when the capacity of the column has been significantly exceeded. [15][16][17][18][19] It has universal applicability, does not suffer from the limitations associated with classical matrix elimination in liquid chromatography, and markedly reduces the column abuse that can occur when the capacity of the column has been significantly exceeded.…”
Section: Determination Of Bromate In Drinking Water 2237mentioning
confidence: 99%
“…monium ions, and allows for the determination of All ammonium standard solutions were prepared sodium-to-ammonium concentration ratios in the from ammonium chloride (Beijing Xinguang Chemiorder of 20 000-to-1. This method requires two cal Reagent Factory, China [18][19][20][21][22]. In this method, a six-step from Yantai, Shandong province in the north of procedure was needed to optimize the 'heart-cut' China.…”
Section: Introductionmentioning
confidence: 99%
“…matrix ions being directed to waste. One such Several methods have been devised to deal with example was for the analysis of sulfite in a variety of samples of this type, normally by coupling the foods [26,27], wherein sulfite anions were bound to a preconcentration procedure to a suitable matrix Dionex AS-2 anion-exchange cartridge, with the elimination procedure. One approach which is suit-bulk of the matrix eluted to waste.…”
Section: Introduction and Scope Of This Reviewmentioning
confidence: 99%