2008
DOI: 10.1016/j.ijrobp.2008.06.1175
|View full text |Cite
|
Sign up to set email alerts
|

Marker Based IGRT in Prostate Radiotherapy - Merits and Pitfalls

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0

Year Published

2009
2009
2010
2010

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(7 citation statements)
references
References 0 publications
0
7
0
Order By: Relevance
“…Similar to MVCT, implanted prostate markers could be used to facilitate the alignment process and help increase the verification accuracy. In marker-based IGRT using kVCBCT, the prostate displacement of ≥3 mm was shown in 82 out of 96 fractions and mostly in the postero-inferior direction 48 . Moreover, the prostate could be deformed to in varying degrees.…”
Section: Clinical Applications Of the Mvct And Kvcbct Systemsmentioning
confidence: 99%
See 2 more Smart Citations
“…Similar to MVCT, implanted prostate markers could be used to facilitate the alignment process and help increase the verification accuracy. In marker-based IGRT using kVCBCT, the prostate displacement of ≥3 mm was shown in 82 out of 96 fractions and mostly in the postero-inferior direction 48 . Moreover, the prostate could be deformed to in varying degrees.…”
Section: Clinical Applications Of the Mvct And Kvcbct Systemsmentioning
confidence: 99%
“…The ability of kVCBCT to visualise soft-tissue organs was an advantage, but the boundaries of prostate, bladder and rectum were only partially differentiable. 48 Moreover, the prostate could be deformed to in varying degrees. Similar to MVCT, implanted prostate markers could be used to facilitate the alignment process and help increase the verification accuracy.…”
Section: Pelvic Regionmentioning
confidence: 99%
See 1 more Smart Citation
“…The kV Xray source can be located between 80 and 100 cm from the machine isocenter, and the MV source is fixed at 100 cm from the machine isocenter. With the X-ray collimator fully open and the imager at the maximum distance from the source, the maximum field size at isocenter is 20 × 27 cm 2 .…”
Section: Hardware Localization Systemsmentioning
confidence: 99%
“…With the amount of inter-and intrafraction motion that occurs in the prostate, it is necessary to use a form of localization prior to treatment. Studies have shown that use of implanted prostate markers with kilovoltage (kV) or megavoltage (MV) imaging of localization or matching is a preferred, accurate, and reliable method for positioning prostate patients for treatment compared with laser-guided external skin alignment [1,2]. Image-guided radiation therapy (IGRT) utilizing integrated kV imaging with the linear accelerator has been performed in the Department of Radiation Oncology at Emory University since 2004.…”
Section: Introductionmentioning
confidence: 99%