MammoSite multilumen catheter: Dosimetry considerations

Abstract: In our initial experience, dosimetric goals can be better achieved using the ML MammoSite balloon when normal structures (skin and ribs) are close to PTV_EVAL with a distance of <7 mm and rib distance of <1 cm. The multiple lumen of ML balloon can optimize dose and reduce excessive dose to rib and skin and therefore minimize the long-term toxicities of rib discomfort, skin fibrosis and fat necrosis.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2012
2012
2016
2016

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 7 publications
(3 citation statements)
references
References 9 publications
(14 reference statements)
0
3
0
Order By: Relevance
“…In addition, there are contraindications that can interfere with dosage planning ( 34 ) : insufficient distance between the tumor and the skin; and an extensive cavity. Its use is not indicated when the tumor cavity is in an area of tissue that cannot be sufficiently covered ( 35 ) . Undesirable anatomic surgical conditions and ineligible histological conditions can also preclude the application of the balloon technique ( 17 ) .…”
Section: Discussionmentioning
confidence: 99%
“…In addition, there are contraindications that can interfere with dosage planning ( 34 ) : insufficient distance between the tumor and the skin; and an extensive cavity. Its use is not indicated when the tumor cavity is in an area of tissue that cannot be sufficiently covered ( 35 ) . Undesirable anatomic surgical conditions and ineligible histological conditions can also preclude the application of the balloon technique ( 17 ) .…”
Section: Discussionmentioning
confidence: 99%
“…This unique study enabled direct comparison between the dosimetric capabilities of the single-lumen and ML-MS catheters by using the same patient cohort. Previous studies comparing single-lumen and ML balloon catheters were carried out on different patient cohorts and used the Contura multilumen balloon (SenoRx Inc., Irvice, CA) (10e13), other than that of Ravi et al (14) who used the ML-MS catheter on 2 patients.…”
Section: Introductionmentioning
confidence: 99%
“…1 For APBI brachytherapy, there are still many choices available, such as low-dose rate versus high-dose rate (HDR), difference devices (balloon types), difference sources 1 Radiation Oncology, Saint Vincent's Medical Center, Bridgeport, CT, USA (electrons vs photons), or timing (intraoperative vs after surgery). 3,4 Previous studies have been done extensively to cover the APBI brachytherapy simulation device selection and comparison, 5,6 treatment planning concerns, 7-10 treatment toxicity, [11][12][13][14][15][16] and clinical outcomes. [17][18][19][20][21][22][23][24][25][26][27][28] However, with the increasing usage of APBI brachytherapy 1 and safety concerns 29,30 for brachytherapy, it is vital to have a single-community hospital experience, which will still be able to help the society to understand APBI brachytherapy treatment safety implementation, clinical outcomes, and help to confirm known results.…”
Section: Introductionmentioning
confidence: 99%