Making Old New Again: HVdc and FACTS in the Northeastern United States and Canada

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
9
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
3
3
3

Relationship

0
9

Authors

Journals

citations
Cited by 19 publications
(10 citation statements)
references
References 4 publications
0
9
0
Order By: Relevance
“…The line-commutated-converter (LCC)-based high-voltage directcurrent (HVDC) technology has been widely adopted in the world because of its advantages in long-distance large-scale transmission [1,2]. Especially in China, in order to address the problem that power centre and load centre are distributed unequally and regional grids are needed to be interconnected, LCC HVDC transmission system has played an important role in transmitting the power from the power centre to load centre and interconnecting regional grids.…”
Section: Introductionmentioning
confidence: 99%
“…The line-commutated-converter (LCC)-based high-voltage directcurrent (HVDC) technology has been widely adopted in the world because of its advantages in long-distance large-scale transmission [1,2]. Especially in China, in order to address the problem that power centre and load centre are distributed unequally and regional grids are needed to be interconnected, LCC HVDC transmission system has played an important role in transmitting the power from the power centre to load centre and interconnecting regional grids.…”
Section: Introductionmentioning
confidence: 99%
“…The disadvantage of the 1PBTBS (one 12-pulse DC circuit) is that if one 6-pulse bridge of 12-pulse DC circuit falls, then the entire system becomes completely lost. The parallel interconnection of two or more 1PBTBSs is used to increase the reliability and capacity of electrical energy exchanging between two AC systems [11], [12]. For example, the Vyborgskaya BTBS project consists of four 1PBTBS units, with each unit rated at 355 MW.…”
Section: Installed Throughoutmentioning
confidence: 99%
“…The residue method has traditionally been used to tune the POD controller parameters [11]. However, the controller settings obtained are dependent on the operating point of the system, and thus, an optimal tuning across multiple operating conditions is not guaranteed [12].…”
Section: Introductionmentioning
confidence: 99%