2017
DOI: 10.1002/acm2.12034
|Get access via publisher |Summarize |Cite
|
Sign up to set email alerts

Lung volume reproducibility under ABC control and self‐sustained breath‐holding

Abstract: An Active Breathing Coordinator (ABC) can be employed to induce breath‐holds during CT imaging and radiotherapy of lung, breast and liver cancer, and recently during lung cancer MRI. The apparatus measures and controls respiratory volume, hence subject lung volume reproducibility is its principal measure of effectiveness. To assess ABC control quality, the intra‐session reproducibility of ABC‐induced lung volumes was evaluated and compared with that reached by applying the clinical standard of operator‐guided … Show more

Search citation statements

Order By: Relevance

Paper Sections

Select...
12
8
3
1

Citation Types

2
23
1
0

Year Published

2017
2017
2025
2025

Publication Types

Select...
18
2
1

Relationship

2
19

Authors

Journals

citations

Cited by 21 publications

(26 citation statements)
references

References 16 publications

2
23
1
0
Order By: Relevance
How this paper cites the one you are viewing
“…Tightly controlling subject breathing patterns (as quantified in Table 2) was advantageous for reducing breathing-related uncertainty. Similar TV variations were seen in a previous study of six human subjects where intraday breath-hold volumes with an active breathing coordinator (ABC) and through self -sustained breathholds had average standard deviations of 99 cc and 226 cc, 40 respectively. Du et al 29 previously demonstrated strong CT-ventilation biomarker reproducibility in anesthetized, mechanically ventilated sheep and reduced reproducibility in free-breathing human subjects.Du also noted that reproducibility was heavily dependent on repeatability of subjects' breathing patterns and respiratory effort.…”
Section: Discussion
supporting
confidence: 84%
“…Tightly controlling subject breathing patterns (as quantified in Table 2) was advantageous for reducing breathing‐related uncertainty. Similar TV variations were seen in a previous study of six human subjects where intraday breath‐hold volumes with an active breathing coordinator (ABC) and through self‐sustained breath‐holds had average standard deviations of 99 cc and 226 cc, 40 respectively. Du et al 29 .…”
Section: Discussion
supporting
confidence: 83%
See 1 more Smart Citation
How this paper cites the one you are viewing
“…Tightly controlling subject breathing patterns (as quantified in Table 2) was advantageous for reducing breathing-related uncertainty. Similar TV variations were seen in a previous study of six human subjects where intraday breath-hold volumes with an active breathing coordinator (ABC) and through self -sustained breathholds had average standard deviations of 99 cc and 226 cc, 40 respectively. Du et al 29 previously demonstrated strong CT-ventilation biomarker reproducibility in anesthetized, mechanically ventilated sheep and reduced reproducibility in free-breathing human subjects.Du also noted that reproducibility was heavily dependent on repeatability of subjects' breathing patterns and respiratory effort.…”
Section: Discussion
supporting
confidence: 84%
“…Tightly controlling subject breathing patterns (as quantified in Table 2) was advantageous for reducing breathing‐related uncertainty. Similar TV variations were seen in a previous study of six human subjects where intraday breath‐hold volumes with an active breathing coordinator (ABC) and through self‐sustained breath‐holds had average standard deviations of 99 cc and 226 cc, 40 respectively. Du et al 29 .…”
Section: Discussion
supporting
confidence: 83%
How this paper cites the one you are viewing
“…ABC devices assisted BH was more stable than self-controlled BHs. The average lung volume variation with ABC was 1.8% of the measured lung volumes (99 mL) and was smaller than the 4.1% (226 mL) variability obtained with the self-sustained BH [85].…”
Section: ) Abdominal Compression
contrasting
confidence: 52%
How this paper cites the one you are viewing
“…Additionally, the ABC device has demonstrated high consistency in controlling lung volumes, highlighting its reliability in delivering reproducible breath-holds. 32 This precision enhances the safety and accuracy of radiation delivery, reinforcing the effectiveness of the ABC device in protecting critical OARs. In contrast, DIBH patient setup based solely on surface guided radiation therapy (SGRT), without complementary imaging guidance, is inherently dependent on patient-specific factors such as setup error, surface irregularities, respiratory behaviour and potential breast deformation.…”
Section: Discussion
mentioning
confidence: 87%