1986
DOI: 10.1103/physrevb.33.5512
|View full text |Cite
|
Sign up to set email alerts
|

Luminescence linewidths of excitons in GaAs quantum wells below 150 K

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

20
261
0
1

Year Published

1998
1998
2018
2018

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 448 publications
(283 citation statements)
references
References 13 publications
20
261
0
1
Order By: Relevance
“…38 The deviation of the fitting curve above 80 K for 0-0 LL and above 90 K for 1-1 LL is possibly associated with carrier delocalization and/or deionized impurities at high temperatures. 39 ⌫ 0 ͑ϳ1.9 meV͒ indicates that the SF pulse duration is shorter than 700 fs ͑ =2ប / ⌫ 0 ͒ while the temperature dependence of B TH ͑T͒ agrees with the dephasing dynamics in a zero-dimensional system.…”
Section: Temperature Dependencementioning
confidence: 51%
“…38 The deviation of the fitting curve above 80 K for 0-0 LL and above 90 K for 1-1 LL is possibly associated with carrier delocalization and/or deionized impurities at high temperatures. 39 ⌫ 0 ͑ϳ1.9 meV͒ indicates that the SF pulse duration is shorter than 700 fs ͑ =2ប / ⌫ 0 ͒ while the temperature dependence of B TH ͑T͒ agrees with the dephasing dynamics in a zero-dimensional system.…”
Section: Temperature Dependencementioning
confidence: 51%
“…We also neglect the change in the exciton effective mass due to the magnetic field because we assume B to be small and the correction is quadratic in B . After the collisional relaxation (local thermalization inside the exciton gas) 15,127 and the phonon relaxation (cooling of the locally equilibrated exciton gas) 128 exciton occupancy n(p B ) "falls" down to the bottom of the shifted parabola (p B ≈ p 0 ). In this state the exciton system is "cold" and the group velocity of excitons averaged over n(p B ) is zero 129 :…”
Section: Physical Realizationmentioning
confidence: 99%
“…In fact, fits of the HWHM of the PL emission of quantum well structures have been used in the past for measuring the T dependence of the homogeneous broadening of excitons. 17 Before going on and discussing the experimental data, let us analyze the method for homogeneous broadening different from Lorentzian. This is because it has been recently pointed out that the phonon sideband in strongly confined QD is likely better approximated by a Gaussian, even if generally it does not follow a simple analytical expression.…”
Section: General Considerationsmentioning
confidence: 99%