2013
DOI: 10.1016/j.yebeh.2012.10.006
|View full text |Cite
|
Sign up to set email alerts
|

Long-term home monitoring of hypermotor seizures by patient-worn accelerometers

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
29
0
1

Year Published

2014
2014
2022
2022

Publication Types

Select...
4
3
1

Relationship

0
8

Authors

Journals

citations
Cited by 51 publications
(32 citation statements)
references
References 19 publications
0
29
0
1
Order By: Relevance
“…Focal dyscognitive seizures without motor phenomena and absence seizures were not detected [19,83,84]. Sensitivity ranges between 16-100%; one study had a FDR of 0.2/day [83,84,86,87,[89][90][91][92]. Seizures were detected 9-60 seconds after seizure onset [84,87].…”
Section: Accelerometry (Acm)mentioning
confidence: 99%
See 1 more Smart Citation
“…Focal dyscognitive seizures without motor phenomena and absence seizures were not detected [19,83,84]. Sensitivity ranges between 16-100%; one study had a FDR of 0.2/day [83,84,86,87,[89][90][91][92]. Seizures were detected 9-60 seconds after seizure onset [84,87].…”
Section: Accelerometry (Acm)mentioning
confidence: 99%
“…The signal is recorded by means of a three-axis motion/accelerometer sensor, a microprocessor, and a small, rechargeable battery, usually placed on a limb [83,84,[86][87][88]. The main challenge is to differentiate seizures from normal, daily, repetitive movements [19,89].…”
Section: Accelerometry (Acm)mentioning
confidence: 99%
“…On the other hand, there are solutions where the gathered data is stored for data analytics [39,40] or even for future use [41][42][43][44]. Finally, complete CC solutions have been also tackled in the literature, including not only the data storage and visualization but also the modelling and classification of the current state of affairs [7,31,32,[45][46][47][48].…”
Section: Introductionmentioning
confidence: 99%
“…ACM, gyroscopes, and magnetometers were proposed in [9] as the BSN, taking advantage of the local Smartphone for analyzing the data and sending e-mails to the medical staff with the patient position. Similar works were presented in [47,48]. LabView has been used for developing a solution as well [35] by using an Arduino ACM sensor to generate alarms that are transmitted to the medical service.…”
Section: Introductionmentioning
confidence: 99%
“…Moreover, a multitude of algorithms for online bio-signal extraction and automatic pathology detection, are ready to be integrated in such a medical body sensor network but are in need for high performance, ergo they consume abundant energy [10][11][12]. On the other hand, the patient's comfort level is affected by the device's dimensions.…”
Section: Introductionmentioning
confidence: 99%