Liquid Chromatographic Determination of Dehydroepiandrosterone (DHEA) in Dietary Supplement Products

Abstract: A liquid chromatographic (LC) method was developed to assess the potency of products that contain dehydroepiandrosterone (DHEA), a precursor hormone synthesized from cholesterol by the human adrenal cortex and converted to potent androgens and/or estrogens in peripheral tissues. Forty-five commercial products (both single and multi-ingredient) were subjected to analysis by the proposed method. A Zorbax Rx C18 column with a mobile phase containing acetonitrile–0.025M phosphate buffer (60 + 40), pH 3.50, and UV … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
21
0
1

Year Published

2008
2008
2019
2019

Publication Types

Select...
5
1
1

Relationship

0
7

Authors

Journals

citations
Cited by 37 publications
(22 citation statements)
references
References 1 publication
0
21
0
1
Order By: Relevance
“…As serum levels of DHEA decline with age, both premenopausal and postmenopausal women experience a lowered libido, diminished sexual function, and a loss of well‐being [7,8]. As an empirical treatment, DHEA is widely used for its anti‐aging and performance‐boosting effects [9]. It has also gained popularity as a medication to improve ovarian response in poor responders, especially women with DOR, during IVF/ICSI treatment.…”
Section: Introductionmentioning
confidence: 99%
“…As serum levels of DHEA decline with age, both premenopausal and postmenopausal women experience a lowered libido, diminished sexual function, and a loss of well‐being [7,8]. As an empirical treatment, DHEA is widely used for its anti‐aging and performance‐boosting effects [9]. It has also gained popularity as a medication to improve ovarian response in poor responders, especially women with DOR, during IVF/ICSI treatment.…”
Section: Introductionmentioning
confidence: 99%
“…Moreover, a column with a size of 2.1 × 150 mm was employed in order to ensure that the antibiotics are detectable after 1 min. Further, the following composi- (Thompson & Carlson, 2000). 1993).…”
Section: Optimization Of Lc-ms/ms Conditionsmentioning
confidence: 99%
“…We chose the last combination, as it produced the strongest signals. Filtration and reconstitution in methanol prior to LC-MS/MS analysis are generally necessary to protect the instrument and the column (Thompson & Carlson, 2000).…”
Section: Optimization Of Lc Conditionsmentioning