Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

11
265
0

Year Published

2007
2007
2017
2017

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 273 publications
(276 citation statements)
references
References 51 publications
(276 reference statements)
11
265
0
Order By: Relevance
“…NBD-diC n PE probes have been used extensively as model phospholipids in the studies of thermodynamics and kinetics of interaction with lipid bilayers and other hydrophobic aggregates, such as serum lipoproteins. [17][18][19] Used as FRET donors, NBD-diC n PE probes form, together with acceptor rhodamine B PE derivatives, a very well-known Förster pair for the studies of membrane organization [20][21][22][23][24] as well as quantification of lipid mixing and exchange. 25 Alternatively, NBD probes can be used as acceptors to chromophores including diphenylhexatriene 26,27 or trans-parinaric acid, 28 or even as donors and acceptors simultaneously in homo-FRET studies.…”
Section: Introductionmentioning
confidence: 99%
“…25 Alternatively, NBD probes can be used as acceptors to chromophores including diphenylhexatriene 26,27 or trans-parinaric acid, 28 or even as donors and acceptors simultaneously in homo-FRET studies. 20 Several fluorescence spectroscopic and microscopic studies have also indicated that, contrary to the vast majority of membrane fluorescent probes, doubly saturated long-chained NBD-diC n PE partitions favourably to liquid ordered (lo) phases in systems displaying lo/liquid disordered phase coexistence, 22,24,29,30 although the phase preference depends both on the probe acyl chain length and the composition of the underlying lipid mixture. 17,31 Despite their wide use in membrane biophysics, the behaviour of NBD-diC n PE probes has so far lacked a characterization using MD.…”
Section: Introductionmentioning
confidence: 99%
“…It has long been recognized that energy transfer between fluorescent membrane probes is eminently suited to the detection and study of coexisting membrane phase domains [19], and a number of groups have adapted FRET experiments to this end during the last decade, or so [e.g., 4,[20][21][22]. Indeed, Loura, de Almeida, Fedorov and Prieto have published several excellent studies [13,[23][24][25][26][27] based on time-resolved measurements of transfer efficiency, ) (t E , and Silvius and Nabi have recently produced a comprehensive review of FRET-based studies of membrane microdomains [28].…”
Section: Discussionmentioning
confidence: 99%
“…And as long as all relevant experimental parameters (e.g., spectrophotometer settings and global probe concentrations) are kept fixed throughout a given experiment, variations in coexisting membrane phases, it may first be noted that (i) on the timescale of typical excited state lifetimes (≤ 10 -8 s) there is little diffusive motion of membrane probes [11]; and that (ii) the characteristic spatial scale, R d , of many membrane phase domains is much larger than the donor-acceptor Förster distance, R 0 , of even the most efficient energy transfer probe pairs (i.e., R 0 ~ 5 nm). For both these reasons, the fraction of overall energy transfer that occurs across domain boundaries should be minimal 2 and the observed (i.e., global average) donor-excited acceptor fluorescence may be approximated as the sum of individual contributions 2 In order to allow for the study of "nanoscopic" membrane domains, which have Rd on the order of 100 nm or smaller [12,13], SP-FRET experiments can simply employ less efficient donor-acceptor pairs (i.e., probe combinations with reduced spectral overlap) in order to ensure that R0 << Rd.…”
Section: Modeling Sp-fret In a Regime Of Coexisting Phasesmentioning
confidence: 99%
“…In phospholipid bilayers, the hydrophobic mismatch between the components in binary mixtures leads to different types of phase diagrams (Mabrey and Sturtevant 1976;de Almeida et al 2005). For PCs, a difference of six carbons in the acyl chain length in the mixture of symmetric dilauroyl-PC/distearoyl-PC produced a rather flattened fluid-gel coexistence line (Mabrey and Sturtevant 1976;Risbo et al 1995).…”
Section: Ceramide Mixturesmentioning
confidence: 99%