2010
DOI: 10.1016/j.jasms.2010.03.039
|View full text |Cite
|
Sign up to set email alerts
|

Laserspray ionization (LSI) ion mobility spectrometry (IMS) mass spectrometry

Abstract: A simple device is described for desolvation of highly charged matrix/analyte clusters produced by laser ablation leading to multiply charged ions that are analyzed by ion mobility spectrometry-mass spectrometry. Thus, for example, highly charged ions of ubiquitin and lysozyme are cleanly separated in the gas phase according to size and mass (shape and molecular weight) as well as charge using Tri-Wave ion mobility technology coupled to mass spectrometry. This contribution confirms the mechanistic argument tha… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

2
111
0

Year Published

2010
2010
2024
2024

Publication Types

Select...
4
3

Relationship

3
4

Authors

Journals

citations
Cited by 54 publications
(113 citation statements)
references
References 22 publications
2
111
0
Order By: Relevance
“…Approximately 20 laser shots were summed for each spectrum. LSII-MS was performed on the SYNAPT G2 by converting the nano-ESI source to a LSII source according to published procedure (54)(55)(56)(57)(58)(59)68 ) using the 337 nm nitrogen laser employed for LSII-MS on the LTQ Velos.…”
Section: Laserspray Ionization Inlet (Lsii) Is a Novel Methods (Supplementioning
confidence: 99%
See 1 more Smart Citation
“…Approximately 20 laser shots were summed for each spectrum. LSII-MS was performed on the SYNAPT G2 by converting the nano-ESI source to a LSII source according to published procedure (54)(55)(56)(57)(58)(59)68 ) using the 337 nm nitrogen laser employed for LSII-MS on the LTQ Velos.…”
Section: Laserspray Ionization Inlet (Lsii) Is a Novel Methods (Supplementioning
confidence: 99%
“…Singly deprotonated ions mass spectrometer is an important LSII parameter in both positive and negative ion mode detection ( 65 ). Ion abundance in LSII is increased by heating the ion transfer capillary ( 53,(68)(69)(70). Using 2,5-DHB on a LTQ Velos mass spectrometer, GD1 could only be analyzed at capillary temperatures between 400°C and the maximum setting of 450°C in the negative ion mode.…”
Section: Tissue Preparationmentioning
confidence: 99%
“…The Waters Corporation (Milford, MA, USA) SYNAPT G2 nanospray source was modified as previously described [4]. Briefly, the laser beam from a Spectra Physics nitrogen 337-VSL-ND-S laser was aimed through the opening created by removal of the LockSpray mechanism and directly in-line with the skimmer entrance.…”
Section: Methodsmentioning
confidence: 99%
“…The nanospray capillary was also removed so that a melting point tube could be attached to the x,y,z-stage normally used to adjust the capillary relative to the ion entrance orifice for ESI. A desolvation device described elsewhere [4] was heated to ca. 250°C.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation