2009
DOI: 10.1016/j.sab.2009.07.024
|View full text |Cite
|
Sign up to set email alerts
|

Laser-induced breakdown spectroscopy for branching ratio and atomic lifetime measurements in singly-ionized neodymium and gallium

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
12
0

Year Published

2010
2010
2023
2023

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 16 publications
(12 citation statements)
references
References 23 publications
0
12
0
Order By: Relevance
“…[207][208][209] In ICP work, Doidge 210 reported branching ratios for the elements Fe, Se, Te, Ge, and Pd. A detailed description of the relative and absolute calibration procedure of a broad band echelle spectrometer has been recently described by Bibinov et al 211,212 In LIBS work, using an echelle spectrometer, Rehse and Ryder 213 have measured the branching ratio from hundreds of transitions of singly ionized Nd and Ga, although the focus of the work was not the calibration of the system.…”
Section: 112mentioning
confidence: 99%
“…[207][208][209] In ICP work, Doidge 210 reported branching ratios for the elements Fe, Se, Te, Ge, and Pd. A detailed description of the relative and absolute calibration procedure of a broad band echelle spectrometer has been recently described by Bibinov et al 211,212 In LIBS work, using an echelle spectrometer, Rehse and Ryder 213 have measured the branching ratio from hundreds of transitions of singly ionized Nd and Ga, although the focus of the work was not the calibration of the system.…”
Section: 112mentioning
confidence: 99%
“…The produced ablation plume was subsequently intersected with a probe beam from a tunable dye laser (Sirah, Cobra-Stretch, DCM dye) that was equipped with a harmonic generator (BBO) and was pumped by A C C E P T E D M A N U S C R I P T ACCEPTED MANUSCRIPT 5 another Nd:YAG laser (Spectra Physics, INDI-10). The UV probe beam was first expanded with a quartz concave lens (focal length: −250 mm) and then converted into a thin sheet-shaped beam by passing through a slit (gap width: 0.5 mm) located in front of the sample to avoid generating interference fringes.…”
Section: Accepted Manuscriptmentioning
confidence: 99%
“…LIBS for the detection of gadolinium in molten glass, in coated stainless steel plates, and in its oxide form have been reported in References [15][16][17]. Lanthanum in molten glass and alloys of neodymium have also been reported [15,[18][19][20][21][22]. Studies to detect samarium as a trace pollutant in soils, and its alloys using the LIBS technique have been published [23,24].…”
Section: Introductionmentioning
confidence: 99%