Abstract: Laser-induced acoustic desorption (LIAD) coupled with a 3-T Fourier transform ion cyclotron resonance mass spectrometer (FT-ICR) allows the simultaneous analysis of both the nonpolar and polar components in petroleum distillates. The LIAD/FT-ICR method was validated by examining model compounds representative of the various classes of polar and nonpolar hydrocarbons commonly found in petroleum. LIAD successfully desorbs all the compounds as intact neutral molecules into the FT-ICR. Electron ionization (EI) at … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

3
91
0

Year Published

2006
2006
2015
2015

Publication Types

Select...
6
2

Relationship

1
7

Authors

Journals

citations
Cited by 70 publications
(94 citation statements)
references
References 47 publications
(65 reference statements)
3
91
0
Order By: Relevance
“…§ Negative ion data were collected with similar parameters and appropriate polarity changes. Petroleum ions were typically singly charged, based on the unit m/z separation between 12 Cn and 13 C1 12 Cn-1 isotopic variants of the same elemental composition (59). FT-ICR mass spectra were internally calibrated with respect to a homologous series of ions present in high abundance in each sample.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…§ Negative ion data were collected with similar parameters and appropriate polarity changes. Petroleum ions were typically singly charged, based on the unit m/z separation between 12 Cn and 13 C1 12 Cn-1 isotopic variants of the same elemental composition (59). FT-ICR mass spectra were internally calibrated with respect to a homologous series of ions present in high abundance in each sample.…”
Section: Methodsmentioning
confidence: 99%
“…We have, to date, resolved and identified Ͼ60,000 distinct elemental monoisotopic elemental compositions, 12 C c 1 H h 14 N n 16 O o 32 S s , from ions in positive-and negativeion ESI and APPI FT-ICR mass spectra of dozens of petroleum crude oil samples. [Species with one or more 13 C, 15 N, 34 S, etc.…”
Section: Typically Of H/c Ratio Vs O/c Ratio the Van Krevelen Plot mentioning
confidence: 99%
See 1 more Smart Citation
“…LIAD has been successfully applied to the mass spectrometric analysis of a wide variety of analytes, including peptides, 10,15 dinucleoside phosphates, 16 saturated hydrocarbon polymers 17,18 and petroleum distillates. 19 An overall experimental characterization of the LIAD technique has been performed. 10,14, 20 However, a more detailed examination of the energies of LIAD evaporated molecules is needed.…”
Section: Introductionmentioning
confidence: 99%
“…Detailed procedures can be found in MALDI manuals, but operator skills and experience are also often important factors. It should be noted that some other interesting and potentially useful methods for sample introduction have been reported, which include, atmospheric pressure MALDI, 18,19 desorption/ionization on silicon nanowires, 20 laser-induced acoustic desorption, 21 ESI-MALDI, 22 electrospray sample deposition (ESD), 23 the use of carbon nanotubes 24 and AnchorChip TM sample preparation. 25 In this study, we wish to report on a new method for sample preparation, the spray deposition method, for use in conjunction with MALDI-TOFMS.…”
Section: Introductionmentioning
confidence: 99%