2010
DOI: 10.1002/ejlt.200900064
|View full text |Cite
|
Sign up to set email alerts
|

Kinetics of commercial olive oil oxidation: Dynamic differential scanning calorimetry and Rancimat studies

Abstract: Four samples of olive oil were oxidized under polythermal (dynamic) conditions in the cell of a normalpressure differential scanning calorimeter (DSC) and in the Metrohm Rancimat apparatus. The DSC experiments were carried out in an oxygen flow atmosphere using different linearly programmed heating rates in the range of 4-20 7C/min. Through DSC exotherms, the extrapolated onset temperatures were determined and used for the assessment of the thermal-oxidative stabilities of the samples. Using the Ozawa-Flynn-Wa… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

7
52
0

Year Published

2014
2014
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 60 publications
(59 citation statements)
references
References 31 publications
7
52
0
Order By: Relevance
“…Determining parameters of oil oxidation kinetics allows us to better assess their oxidation stability, suitability for processing and resistance to high temperatures during processing and storage [16,17,20,36]. Oxidation times determined for Rancimat (s on ) and PDSC (s max ) techniques presented in Table 2 enabled to prepare the graphical dependences between logarithm of s max and s on and temperature (Figs.…”
Section: Kinetic Analysis Of Rancimat and Pdsc Datamentioning
confidence: 99%
See 2 more Smart Citations
“…Determining parameters of oil oxidation kinetics allows us to better assess their oxidation stability, suitability for processing and resistance to high temperatures during processing and storage [16,17,20,36]. Oxidation times determined for Rancimat (s on ) and PDSC (s max ) techniques presented in Table 2 enabled to prepare the graphical dependences between logarithm of s max and s on and temperature (Figs.…”
Section: Kinetic Analysis Of Rancimat and Pdsc Datamentioning
confidence: 99%
“…Metrohm Rancimat (Europe) test and OSI-oxidative stability index (USA)-are commonly applied for analysis of edible oils [16,17], however, they cannot always be successfully used to analyze cold-pressed oils, despite being useful in assessing refined oils. Studies on oil oxidation using the DSC technique, under both isothermal (constant operating temperature) and dynamic conditions (linear temperature growth), have been carried out so far [17][18][19][20]. Nevertheless, studies were mostly conducted on refined oils [17,20,21].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…In order to maintain a healthy product, it is important that lipids are oxidatively stable [12]. Differential scanning calorimetry (DSC) is one of the most popular methods for the appraisal of the oxidative stability of oils and fats [16]. It is based on measuring of the induction times of oils oxidation.…”
Section: Introductionmentioning
confidence: 99%
“…Classical methods are based on ''wet chemistry'' [19]. Nowadays, instrumental methods are commonly used as they are faster, more precise, have wider scope of detection, and are more objective [20]. Differential scanning calorimetry (DSC) is a nonchemical method to determine fat quality parameters [17,[21][22][23].…”
Section: Introductionmentioning
confidence: 99%