2013
DOI: 10.1088/0741-3335/55/12/125008
|View full text |Cite
|
Sign up to set email alerts
|

Kinetic equilibrium reconstruction on EAST tokamak

et al.

Abstract: Plasma equilibrium is an important basis for tokamak plasma research. The equilibrium reconstructed from experimental diagnostics is a key element for experiments analysis and for theory study. The kinetic equilibrium has the profiles information (current or safety factor profile, kinetic pressure profile), which are key issues for some studies of physics. With the constraints of magnetic measurements, pressure profile and edge current profile, we achieved the first reconstructed kinetic equilibrium on EAST to… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
44
0

Year Published

2014
2014
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 56 publications
(45 citation statements)
references
References 26 publications
1
44
0
Order By: Relevance
“…The EAST equilibrium used here was reconstructed by the EFIT code 45 by using the constraints from experimental diagnostics in EAST discharge #38300 at 3.9 s. 46 Figure 5 plots the flux surfaces of the equilibrium and the flux coordinates grids within the last closed flux surface (LCFS) used in the numerical calculation. The equilibrium is a double-null configuration with the LCFS connected with the lower X point.…”
Section: Taes In East Discharge #38300mentioning
confidence: 99%
“…The EAST equilibrium used here was reconstructed by the EFIT code 45 by using the constraints from experimental diagnostics in EAST discharge #38300 at 3.9 s. 46 Figure 5 plots the flux surfaces of the equilibrium and the flux coordinates grids within the last closed flux surface (LCFS) used in the numerical calculation. The equilibrium is a double-null configuration with the LCFS connected with the lower X point.…”
Section: Taes In East Discharge #38300mentioning
confidence: 99%
“…Because in EAST H-mode discharges, the plasma density and temperature profiles are not well measured experimentally, especially near the pedestal, we use the joint DIII-D experimentally measured data of temperature and density profiles (shot 154406), which is similar to those in the EAST H-mode discharge (shot 38300). 28 The electron temperature profile and density profile are shown in Fig. 7.…”
Section: Numerical Results and Discussionmentioning
confidence: 99%
“…But for H-mode discharges, the plasmas density and temperature profiles are much different, and the experimental data will be used. 28,29 …”
Section: B Plasma Equilibrium and Magnetic Topology With Magnetic Ismentioning
confidence: 99%
“…The SXR measurements and equilibrium results from kinetic EFIT (k-EFIT) (Li et al. 2013; Qian et al. 2017) show that the fishbone instability is located inside the q = 1 surface, corresponding to ρ ~ 0.15 ( ρ is the square root of the normalized toroidal flux), as shown in figure 3( c ).…”
Section: Dependence Of Fishbone Cycle Frequency On Plasma Parametersmentioning
confidence: 99%