Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
33
0

Year Published

2012
2012
2023
2023

Publication Types

Select...
8
1

Relationship

3
6

Authors

Journals

citations
Cited by 76 publications
(33 citation statements)
references
References 13 publications
0
33
0
Order By: Relevance
“…In this paper, a four-wheel direct-drive scheme is used, so the number of poles is relatively high. Considering both fault-tolerant capability and power density, the slot/pole combinations for five-phase fault-tolerant PMSMs which satisfy 2p = Q ± 2 (where Q is number of slots, and 2p is number of poles) are proposed [36]. The rotor losses on such slot/pole combinations are thoroughly investigated in [15,19], and the analysis results indicate that in comparison with the low pole-number choice (2p = Q − 2), the high pole-number choice (2p = Q + 2) leads to higher rotor losses, which will reduce the power density.…”
Section: Machine Specification and Slot/pole Combinations Choicementioning
confidence: 99%
“…In this paper, a four-wheel direct-drive scheme is used, so the number of poles is relatively high. Considering both fault-tolerant capability and power density, the slot/pole combinations for five-phase fault-tolerant PMSMs which satisfy 2p = Q ± 2 (where Q is number of slots, and 2p is number of poles) are proposed [36]. The rotor losses on such slot/pole combinations are thoroughly investigated in [15,19], and the analysis results indicate that in comparison with the low pole-number choice (2p = Q − 2), the high pole-number choice (2p = Q + 2) leads to higher rotor losses, which will reduce the power density.…”
Section: Machine Specification and Slot/pole Combinations Choicementioning
confidence: 99%
“…The switching vectors of the five-phase six-leg inverter are defined in equation (3). Assuming that ω is the fundamental frequency of the output phase voltages, through the transform of (3), the (10k±1)th harmonics of the phase voltages can be equivalently expressed as circular rotating space vectors with the frequency of (10k±1)ω in the stationary ab coordinate system, while the (10k±3)th harmonics of the phase voltages can be equivalently expressed as circular rotating space vectors with the frequency of (10k±3)ω in the stationary xy coordinate system [16]- [20].…”
Section: A Definition Of Switching Vectorsmentioning
confidence: 99%
“…they should avoid as much as possible electric, magnetic, physical and thermal coupling [15,16]. Magnetic isolation allows minimizing voltages induced in adjacent phases due to a fault current in the damaged phase.…”
Section: Restrictions For Maximizing Fault Tolerancementioning
confidence: 99%
“…Restrictions imposed in this paper to ensure a high level of fault tolerance capability in the analyzed three-phase AFPM are summarized below [16], 1. Non-overlapping single-layer fractional-slot concentrated windings are used.…”
Section: Restrictions For Maximizing Fault Tolerancementioning
confidence: 99%