2015
DOI: 10.1016/j.etp.2015.07.005
|View full text |Cite
|
Sign up to set email alerts
|

Investigating the cytotoxicity of iron oxide nanoparticles in in vivo and in vitro studies

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
9
0
3

Year Published

2016
2016
2024
2024

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 25 publications
(17 citation statements)
references
References 28 publications
2
9
0
3
Order By: Relevance
“…Data was analyzed using one‐way or two‐way analysis of variances (ANOVA) followed by posthoc Tukey comparison test using the mean of each treatment group in Prism (Version 8). Where relevant, data are presented as the mean ± standard error (Ghasempour, Shokrgozar, Ghasempour, & Alipour, ). Mean of every treatment was compared to the control and significance was determine and denoted by (*) for p < .05, (**) for p < .01, (***) for p < .001, and for p < .0001.…”
Section: Methodsmentioning
confidence: 99%
“…Data was analyzed using one‐way or two‐way analysis of variances (ANOVA) followed by posthoc Tukey comparison test using the mean of each treatment group in Prism (Version 8). Where relevant, data are presented as the mean ± standard error (Ghasempour, Shokrgozar, Ghasempour, & Alipour, ). Mean of every treatment was compared to the control and significance was determine and denoted by (*) for p < .05, (**) for p < .01, (***) for p < .001, and for p < .0001.…”
Section: Methodsmentioning
confidence: 99%
“…Positively charged IONPs were shown to be more toxic, since they undergo nonspecific interactions and adsorptive endocytosis with the negatively charged cell membrane, thus increasing their intracellular accumulation and affecting cell membrane integrity [ 218 ]. Other factors such as concentration, type of coating, form of administration, as well as the cell line may explain the different results for IONPs toxicity [ 21 , 22 , 23 , 25 , 26 , 66 , 71 , 72 , 96 , 97 , 98 , 163 , 214 , 215 , 219 , 220 , 221 , 222 , 223 , 224 , 225 , 226 , 227 , 228 , 229 , 230 , 231 , 232 , 233 , 234 , 235 , 236 , 237 , 238 , 239 , 240 , 241 , 242 , 243 , 244 , 245 , 246 , 247 , 248 ], as shown in Table 1 .…”
Section: Ionps Toxicitymentioning
confidence: 99%
“…5D, incubation with nanorods did not cause significant early apoptotic and late apoptotic/necrotic cell death after 24 or 48 h of incubation, evaluated by apoptotic Annexin V/PI staining assay. In summary, this iron oxide nanorods have a high degree of biocompatibility related to other ellipsoidal magnetic nanoparticles, bearing in mind that cytotoxicity has been evaluated for periods not exceeding 24 h46.…”
mentioning
confidence: 99%