2019
DOI: 10.1016/j.sab.2018.12.013
|View full text |Cite
|
Sign up to set email alerts
|

Investigating silicon wafer based substrates for dried-droplet analysis by Laser-Induced Breakdown Spectroscopy

Abstract: This work communicates a critical assessment on the analytical capability of the three silicon wafer-based substrates; crystalline silicon (c-Si), oxide-coated silicon (SiO 2 -Si), and nitride-coated silicon (Si 3 N 4 -Si), for drieddroplet analysis by laser-induced breakdown spectroscopy. The methodology consists of loading, drying and analyzing steps. First, nanoliter volume of droplets are manually loaded onto the substrate and dried at room temperature. Then, the dry residue is subjected to high peak power… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
3
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
10

Relationship

0
10

Authors

Journals

citations
Cited by 21 publications
(6 citation statements)
references
References 29 publications
0
3
0
Order By: Relevance
“…18,19 Literature shows that the double pulse technique increases the liquid LIBS signal and thereby its sensitivity by using an extra laser pulse to preheat the plasma-induced by the laser in a liquid environment. [20][21][22][23][24][25] In addition, resonance LIBS by choosing a suitable laser wavelength to employ, circulating the sample through a liquid jet, [26][27][28][29] creation of aerosols 30,31 and liquid droplets, 32,33 liquid to solid transformation using different substrates, [34][35][36][37][38][39][40][41] etc., are the other proposed methods for liquid LIBS analysis till date. Among them, adding the components to the experimental setup is limited by the system cost and complexity, and the liquid jet method is limited by the availability of sample volume.…”
Section: Introductionmentioning
confidence: 99%
“…18,19 Literature shows that the double pulse technique increases the liquid LIBS signal and thereby its sensitivity by using an extra laser pulse to preheat the plasma-induced by the laser in a liquid environment. [20][21][22][23][24][25] In addition, resonance LIBS by choosing a suitable laser wavelength to employ, circulating the sample through a liquid jet, [26][27][28][29] creation of aerosols 30,31 and liquid droplets, 32,33 liquid to solid transformation using different substrates, [34][35][36][37][38][39][40][41] etc., are the other proposed methods for liquid LIBS analysis till date. Among them, adding the components to the experimental setup is limited by the system cost and complexity, and the liquid jet method is limited by the availability of sample volume.…”
Section: Introductionmentioning
confidence: 99%
“…. [6][7][8][9][10]. An alternative to circumvent this problem can be the use of sample preparation procedures able to concentrate the target analytes to a level above the detection limits of LIBS.…”
Section: J O U R N a L P R E -P R O O Fmentioning
confidence: 99%
“…The techniques used for elemental analysis of microvolume samples are generally coupled with sample introduction systems. Examples of such systems include nano-and micro-nebulisers, 6 paper spray ionisation, 28 piezoelectric microdispensing, 29 capillary electrophoresis, 30 microfluidic systems, 31,32 dried microdroplets on substrates (such as silicon), 33 and matched with laser ablation systems, 34,35 the enchantement of LIBS nanoparticules, 9,15 and electrodynamic balances. 36,37 All these systems are restricted to liquid samples; therefore, dilution is often required.…”
Section: Introductionmentioning
confidence: 99%