2000
DOI: 10.1002/(sici)1099-159x(200001/02)8:1<113::aid-pip306>3.3.co;2-3
|Get access via publisher |Summarize |Cite
Inverters—critical photovoltaic balance‐of‐system components: status, issues, and new‐millennium opportunities
Search citation statements
Paper Sections
Select...
8
2
0
0
Citation Types
0
9
0
0
Year Published
2003
2024
Publication Types
Select...
6
2
1
Relationship
0
9
Authors
Journals
Cited by 9 publications
(9 citation statements)
References 0 publications
0
9
0
0
Abstract
Smart CitationsHow this paper cites the one you are viewing
“…The failures of PV systems are majorly ascribed to inverter failures [61][62][63]. However, some case may be attributed to various sources such a human and natural cause, batteries [50,60,64], and charge controller as in the case of the solar PV street lighting systems [17], [64].Thus, considering the reliability of the systems from Table 1, it can be deduced that 2.86% of the LED, 2.86% of the panels, 14.29% of the batteries and 28.6% of the charge controllers failed to meet the minimum required lifespan (LED: 6-8 years, solar panel: 20-25 years, battery: 4-6 years and charge controller: 5-15 years) respectively.…”
Section: Reliability Analysis
mentioning
confidence: 99%
Abstract
Smart CitationsHow this paper cites the one you are viewing
“…The failures of PV systems are majorly ascribed to inverter failures [61][62][63]. However, some case may be attributed to various sources such a human and natural cause, batteries [50,60,64], and charge controller as in the case of the solar PV street lighting systems [17], [64].Thus, considering the reliability of the systems from Table 1, it can be deduced that 2.86% of the LED, 2.86% of the panels, 14.29% of the batteries and 28.6% of the charge controllers failed to meet the minimum required lifespan (LED: 6-8 years, solar panel: 20-25 years, battery: 4-6 years and charge controller: 5-15 years) respectively.…”
Section: Reliability Analysis
mentioning
confidence: 99%
Abstract
Smart CitationsHow this paper cites the one you are viewing
“…Internal refers to fault conditions within the inverter which cannot be easily identified. Other categories capture events such as wiring, inoperative switches, and unknown event that signal a fault condition [10], [17]- [18]. In this analysis, the five matrix events cover modular fan functioning issue and replacement, switching transistor issue and its replacement, the two controller events indicated blown PCU card and replacement, the two internal events confirmed auto reset indication, the five different interlock events contains inverter auto trip and nesting rodents, the two other events involved loose connections, inverter at sleep mode and unknown cases.…”
Section: Component Total Repair Time
mentioning
confidence: 99%
Abstract
Smart CitationsHow this paper cites the one you are viewing
“…Although inverters have experienced great evolution in the last decade, even today they still have the bad reputation to be considered one of the most critical BOS of a RES [11]. In the particular case of PV RE systems, in which PV modules can present an expected lifetime of 25 years [12], inverters still to be a critical component.…”
Section: A1 Reliability
mentioning
confidence: 99%
