2020
DOI: 10.1001/jamaneurol.2019.3531
|View full text |Cite|
|
Sign up to set email alerts
|

Interrater Reliability of Experts in Identifying Interictal Epileptiform Discharges in Electroencephalograms

Abstract: The validity of using electroencephalograms (EEGs) to diagnose epilepsy requires reliable detection of interictal epileptiform discharges (IEDs). Prior interrater reliability (IRR) studies are limited by small samples and selection bias.OBJECTIVE To assess the reliability of experts in detecting IEDs in routine EEGs. DESIGN, SETTING, AND PARTICIPANTSThis prospective analysis conducted in 2 phases included as participants physicians with at least 1 year of subspecialty training in clinical neurophysiology. In p… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

5
67
1
1

Year Published

2020
2020
2023
2023

Publication Types

Select...
8
1

Relationship

1
8

Authors

Journals

citations
Cited by 76 publications
(74 citation statements)
references
References 50 publications
5
67
1
1
Order By: Relevance
“…following standard criteria 30 ; (2) using a validated commercial automated wavelet-based detector, Persyst 31,32 ; and (3) using SpikeNet, a validated automated spike detector developed at our institution. 33,34 For each method, all available non-REM sleep epochs were included (mean = 15.2 minutes, range = 4-48 minutes), and a spike rate for each hemisphere was calculated. To minimize artifactual detections, only spikes detected as maximal in the central and temporal channels (consistent with classic CECTS neurophysiology) were included.…”
Section: Eeg Data Acquisition and Preprocessingmentioning
confidence: 99%
See 1 more Smart Citation
“…following standard criteria 30 ; (2) using a validated commercial automated wavelet-based detector, Persyst 31,32 ; and (3) using SpikeNet, a validated automated spike detector developed at our institution. 33,34 For each method, all available non-REM sleep epochs were included (mean = 15.2 minutes, range = 4-48 minutes), and a spike rate for each hemisphere was calculated. To minimize artifactual detections, only spikes detected as maximal in the central and temporal channels (consistent with classic CECTS neurophysiology) were included.…”
Section: Eeg Data Acquisition and Preprocessingmentioning
confidence: 99%
“…Manual detection of epileptiform activity on EEG demonstrates inconsistent interrater agreement; however, review by a neurophysiology-trained specialist, as in this study, may increase reliability. 33,41,42 The Persyst algorithm, although validated, has been previously associated with a high rate of false positives. 43 In its validation study, the SpikeNet algorithm was directly compared to neurophysiology-trained experts and Persyst, exceeding both in performance.…”
Section: F I G U R Ementioning
confidence: 99%
“…Given the wealth of evidence [33][34][35][36] describing the variability between expert EEG reviewers, whether due to human error or to differences in interpretation, we sought to contextualize the observed diagnostic accuracy of the seizure detection algorithm by quantifying the inter-rater variability. We calculated the sensitivity and specificity of identifying EEGs with status epilepticus for each of the experts that reviewed at least 250 h of EEG.…”
Section: Discussionmentioning
confidence: 99%
“…In einer rezenten Studie [4] zeigte sich zwar eine substanzielle Übereinstimmung von 9 erfahrenen EEG-Befundern hinsichtlich des Vorhandenseins von ETPs in einem gegebenen EEG (mittlere prozentuale Übereinstimmung 80,9 %, mittleres Kappa 69,4 %), die Übereinstimmung bei der Annotation einzelner ETPs war jedoch lediglich moderat (mittlere prozentuale Übereinstimmung 72,4 %, mittleres Kappa 48,7 %). Die Autoren erklären die Unterschiede bei der Annotation einzelner ETPs durch unterschiedliche subjek tive individuelle Schwellenwer te der verschiedenen EEG-Befunder für die binäre Entscheidung ETP vs. kein ETP, die sich durch wenige morphologische Eigenschaften erklären ließen [4]. Alternativ könnte man das Spike-Detektionsprogramm auf einzelne EEG-Befunder individuell trainieren und zuschneiden.…”
Section: Take Home Messageunclassified