2016
DOI: 10.1109/tie.2016.2577552
|View full text |Cite
|
Sign up to set email alerts
|

Influence of Third Harmonic Back EMF on Modeling and Remediation of Winding Short Circuit in a Multiphase PM Machine With FSCWs

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
16
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 38 publications
(16 citation statements)
references
References 27 publications
0
16
0
Order By: Relevance
“…Dash above d-q current in the second equation indicates complex conjugate. The first equation of (10) and (11) sets the constraint that the sum of the current sharing coefficients k1,2,3 should always be equal to three. If this is respected, the first equations of (10) and (11) can be omitted from further analysis.…”
Section: Nine-phase Machine Modellingmentioning
confidence: 99%
See 2 more Smart Citations
“…Dash above d-q current in the second equation indicates complex conjugate. The first equation of (10) and (11) sets the constraint that the sum of the current sharing coefficients k1,2,3 should always be equal to three. If this is respected, the first equations of (10) and (11) can be omitted from further analysis.…”
Section: Nine-phase Machine Modellingmentioning
confidence: 99%
“…The power of multi-MW wind turbines has reached 8 MW [2][3][4]. Although the majority of WECS use three-phase machines [4], there is a growing interest in using multiphase machines [5][6][7][8][9][10]. When compared to the three-phase equivalents, multiphase machines have lower current/power per phase, lower torque ripple and above all are inherently fault tolerant [11][12][13].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Assuming that the first set of three-phase windings is normal, and the ISCF occurs in coil 12 of the C2 phase winding which belongs to the second set of three-phase windings in the DRPMSM, the voltage equations of the first set of normal three-phase windings remain unchanged and can be expressed as Equation (8). Thus, the following discussions only focus on the second set of three-phase windings.…”
Section: The Mathematical Models Of the Drpmsmmentioning
confidence: 99%
“…The common faults of motors are winding insulation faults [8][9][10], among which the ISCF in stator coil is more common and can seriously affect the normal operation of motors [11,12]. Therefore, it is significant to detect the ISCF [13,14] and the set of faulty windings in the DRPMSM online.…”
Section: Introductionmentioning
confidence: 99%