2019
DOI: 10.26582/k.51.2.5
|View full text |Cite
|
Sign up to set email alerts
|

Influence of occlusal thickness of custom-made mouthguards on ventilatory parameters, rate of perceived exertion, and peak velocity attained during an incremental test

Abstract: Custom-made mouthguards are used to prevent orofacial injuries arising from falls and knocks. It has been observed that thicker custom-made mouthguards transmit less force to the mouth owing to their higher energy absorption capacity. However, it is believed that thicker custom-made mouthguards can alter ventilation during exercise because of the higher resistance or restriction of oral airflow. The purpose of this study was to investigate if a thicker custom-made mouthguard (occlusal thickness of 5 mm; 5MG) a… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(2 citation statements)
references
References 27 publications
0
2
0
Order By: Relevance
“…to not impair overall sports activities and/or performance, [29][30][31] including negligible effects on cardiorespiratory endurance and not impairing ventilatory function. [32][33][34] Some reports suggest that particular SM designs improve physical performance function 27,[35][36][37] and aerobic capacity. 26,38 However, published research overall suggests that SM do not provide superior improvement in general fitness parameters.…”
Section: Sm Compliancementioning
confidence: 99%
See 1 more Smart Citation
“…to not impair overall sports activities and/or performance, [29][30][31] including negligible effects on cardiorespiratory endurance and not impairing ventilatory function. [32][33][34] Some reports suggest that particular SM designs improve physical performance function 27,[35][36][37] and aerobic capacity. 26,38 However, published research overall suggests that SM do not provide superior improvement in general fitness parameters.…”
Section: Sm Compliancementioning
confidence: 99%
“…Non‐compliance with the use of Type 1 and Type 2 SM has been reported 26 due to discomfort, interfering with communication, perceived breathing difficulties, 27,28 and negatively affecting exercise capacity 21 . Conversely, well‐adapted Type 3 SM have been reported to not impair overall sports activities and/or performance, 29–31 including negligible effects on cardiorespiratory endurance and not impairing ventilatory function 32–34 . Some reports suggest that particular SM designs improve physical performance function 27,35–37 and aerobic capacity 26,38 .…”
Section: Introductionmentioning
confidence: 99%