Abstract:Endovascular repair of recoarctation was indicated. For strategy optimization, a reconstruction and 3D printing model of the pathological aorta was performed (Figure 1).The procedure was carried out under neuroleptanalgesia, with continuous central monitoring of differential pressure and a rapid pacemaker during stent placement. An AltoSa-XL-Gemini Balloon Catheter of 18 mm diameter and 50 length (AndraTec GmbH, Koblenz, Germany) was used over which a self-expandable covered Andrastent 48XL stent (PTFE-tube co… Show more
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.