2017
DOI: 10.21037/jgo.2016.12.10
|View full text |Cite
|
Sign up to set email alerts
|

Individualized 4-dimensional computed tomography proton treatment for pancreatic tumors

Abstract: IntroductionThe utilization of proton therapy has increased sharply with an increasing number of proton centers opening within the United States. The challenges of accurately delivering particle therapy increase over photon based techniques due to the Bragg peak and sharp energy fall off. Thus as intrafractional motion occurs, the water-equivalent path length (WPL) can vary as organs of different density pass through the particle's path, resulting in under coverage of the planning tumor volume (PTV) and higher… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2018
2018
2021
2021

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(3 citation statements)
references
References 14 publications
0
3
0
Order By: Relevance
“…Volumetric kV IG is also used, and its use is becoming more widespread. 78 Other developmental IG or "direct" image verification systems include surface (or its surrogate) imaging systems, proton imaging, [79][80][81][82][83][84][85][86][87][88][89][90][91] prompt gamma (p,γ) imaging, [92][93][94][95][96][97][98][99][100] and proton-PET (p,β+). [101][102][103][104][105][106][107][108][109] If any of these complementary systems are to be used clinically, then special care must be taken during commissioning to align the complementary system to the standard system.…”
Section: Commissioning Image Guidance Systems For Proton Therapymentioning
confidence: 99%
“…Volumetric kV IG is also used, and its use is becoming more widespread. 78 Other developmental IG or "direct" image verification systems include surface (or its surrogate) imaging systems, proton imaging, [79][80][81][82][83][84][85][86][87][88][89][90][91] prompt gamma (p,γ) imaging, [92][93][94][95][96][97][98][99][100] and proton-PET (p,β+). [101][102][103][104][105][106][107][108][109] If any of these complementary systems are to be used clinically, then special care must be taken during commissioning to align the complementary system to the standard system.…”
Section: Commissioning Image Guidance Systems For Proton Therapymentioning
confidence: 99%
“…For patients using 4DCT, an internal target volume (ITV) was defined to encompass the enhancing or hypoattenuating lesion on the maximum intensity projection (MIP) scan (31). For patients using SDX, gross tumor volume (GTV) was defined to encompass the enhancing or hypoattenuating lesion on the CT scan with contrast.…”
Section: Immobilization and Tumor Volume Definitionmentioning
confidence: 99%
“…In this scope, robust planning strategies of pancreatic cancer patients have been investigated based on repeated 3DCT images to investigate inter-fractional motion (Steitz et al 2016, Batista 2017. Moreover, the suitability of 4DCT for planning purposes has been analyzed (Knecht et al 2017) and interfractional anatomical changes have been investigated by means of daily cone-beam CTs (Houweling et al 2016).…”
Section: Introductionmentioning
confidence: 99%