Increased speed and image quality in single‐shot fast spin echo imaging via variable refocusing flip angles

Abstract: Purpose To develop and validate clinically a single shot fast spin echo (SSFSE) sequence utilizing variable flip angle refocusing pulses to shorten acquisition times via reductions in specific absorption rate (SAR) and improve image quality Materials and Methods A variable refocusing flip angle SSFSE sequence (vrfSSFSE) was designed and implemented, with simulations and volunteer scans performed to determine suitable flip angle modulation parameters. With IRB approval/informed consent, patients referred for … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

3
51
0

Year Published

2016
2016
2019
2019

Publication Types

Select...
6

Relationship

4
2

Authors

Journals

citations
Cited by 28 publications
(54 citation statements)
references
References 13 publications
3
51
0
Order By: Relevance
“…The signal decay that leads to blurring is partially mitigated by reducing ETLs and interleaving slices in multi-shot 2D FSE (1). Variable refocusing flip angles have also been used to reduce blurring in single-shot 2D FSE (59). We plan to explore the application of T 2 Shuffling to 2D FSE to further reduce blurring due to long ETLs as well as resolve multiple image contrasts.…”
Section: Discussionmentioning
confidence: 99%
“…The signal decay that leads to blurring is partially mitigated by reducing ETLs and interleaving slices in multi-shot 2D FSE (1). Variable refocusing flip angles have also been used to reduce blurring in single-shot 2D FSE (59). We plan to explore the application of T 2 Shuffling to 2D FSE to further reduce blurring due to long ETLs as well as resolve multiple image contrasts.…”
Section: Discussionmentioning
confidence: 99%
“…The vrfSSFSE pulse sequence was implemented as described previously (13). In brief, the refocusing flip angle approach developed for three-dimensional FSE imaging described by Busse et al (11) was adapted to the case of two-dimensional SSFSE imaging.…”
Section: Vrfssfse Pulse Sequencementioning
confidence: 99%
“…Of the refocusing flip angle parameters (a init , a min , a cent , and a last ), image quality is known to be most dependent on a min ; in addition to reducing SAR, lowering a min leads to relative prolongation of T2 decay, and the resultant stabilization of signal over the echo train should reduce blurring (13). However, lower flip angles lead to a greater dependence on longer refocusing pathways in the echo train, creating longer time periods over which phase shifts from motion can accumulate and result in signal loss (18).…”
Section: Technical Developments: Variable Refocusing Flip Angle Singlmentioning
confidence: 99%
See 1 more Smart Citation
“…Both minimum echo time (TE ¼ 30.4 ms) as well as repetition time (TR ¼ 800 ms) were used in a multi-slice sequence with slice interleaving using a skip factor of 4 (i.e., in a 12 slice sequence, slice were acquired with the order of [1,5,9,2,6,10,3,7,11,4,8,12]). Images were acquired by doubling the field-of-view to better visualize the intermediate aliasing caused by any instability in the nCPMG echotrain that arises for low refocusing flip angles.…”
Section: Phantom Scanningmentioning
confidence: 99%