Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
58
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
5
4

Relationship

0
9

Authors

Journals

citations
Cited by 178 publications
(58 citation statements)
references
References 9 publications
0
58
0
Order By: Relevance
“…This approach outperforms SSD and RetinaNet in terms of speed and it is competitive in terms of accuracy in detecting large objects 2 (Liu et al, 2018) (Li et al, 2020). Moreover, recent works such as (Hossain and Lee, 2019), (Sadykova et al, 2019), (Opromolla et al, 2019) and (Chen and Miao, 2020) achieved good performance in applications involving RPAs and real-time object detection using YOLOv2.…”
Section: Proposal-free (One Shot) Methodsmentioning
confidence: 90%
“…This approach outperforms SSD and RetinaNet in terms of speed and it is competitive in terms of accuracy in detecting large objects 2 (Liu et al, 2018) (Li et al, 2020). Moreover, recent works such as (Hossain and Lee, 2019), (Sadykova et al, 2019), (Opromolla et al, 2019) and (Chen and Miao, 2020) achieved good performance in applications involving RPAs and real-time object detection using YOLOv2.…”
Section: Proposal-free (One Shot) Methodsmentioning
confidence: 90%
“…Therefore, the chosen number k of clustering centers for the dataset CCIN_detection was 12, and 12 cluster centers were further divided into three different detection headers. The corresponding anchor boxes for insulator multiscale prediction were obtained as follows: (43,19)…”
Section: Anchor Boxes Clusteringmentioning
confidence: 99%
“…However, the samples used for training were limited, and the processing speed of a single image needed to be improved. In the work of [43], the YOLOv2 network was applied to transmission lines, inspecting systems for insulator detection. To solve the problem of lacking samples, several augmentation techniques were employed to avoid overfitting.…”
Section: Introductionmentioning
confidence: 99%
“…Insulators of Brazil's medium voltage overhead distribution networks are typically built outdoors and are thus exposed to environmental variations [14]. Contamination in insulators does not represent a failure in the system, however, the high concentration of contaminants can increase surface conductivity and impair the insulation of these components, for this reason, this condition needs to be monitored [15]- [17].…”
Section: Evaluation Of Insulators Contaminationmentioning
confidence: 99%