2002
DOI: 10.1002/mrm.10112
|View full text |Cite
|
Sign up to set email alerts
|

In vivo 1H2O T measurement in the human occipital lobe at 4T and 7T by Carr‐Purcell MRI: Detection of microscopic susceptibility contrast

Abstract: A high-resolution spin-echo imaging method is presented (called CP-LASER) which exploits the spin refocusing capability of an adiabatic Carr-Purcell (CP) pulse sequence to measure apparent 1 H 2 O transverse relaxation (T 2 † ) and generate contrast based on microscopic tissue susceptibility. High-resolution CP-LASER images of the human occipital lobe were acquired at four different echo times from six subjects at 4T and eight subjects at 7T to investigate the effect of magnetic field strength (B 0 ) and the C… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

12
132
1

Year Published

2003
2003
2021
2021

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 111 publications
(145 citation statements)
references
References 40 publications
12
132
1
Order By: Relevance
“…This resulted from combined effects of interecho spacing time on the measurements of both blood and tissue T 2 . Similar findings on the T 2 change with have been reported in the gray and white matter of the brain (19). However, was not increased beyond 11.1 msec because the data acquisition window was limited owing to a relatively short RR interval (Ϸ 700 msec).…”
Section: Discussionsupporting
confidence: 84%
See 1 more Smart Citation
“…This resulted from combined effects of interecho spacing time on the measurements of both blood and tissue T 2 . Similar findings on the T 2 change with have been reported in the gray and white matter of the brain (19). However, was not increased beyond 11.1 msec because the data acquisition window was limited owing to a relatively short RR interval (Ϸ 700 msec).…”
Section: Discussionsupporting
confidence: 84%
“…In the myocardial vascular network, a simplified model was used to describe the myocardial tissue T 2t component (18,19), with the following equation:…”
Section: Relationship Of Myocardial T 2 and Oxygenationmentioning
confidence: 99%
“…In practice, the high-field NMR spectra of the tissue samples are dominated by the broad, featureless water peak due to fast decay of the transverse magnetization under radiation damping, as well as inhomogeneous broadening in the presence of susceptibility variations. On the other hand, microscopic susceptibility gradients have been shown to change the apparent T* 2 relaxation times of water in GM and WM to different extents, leading to contrast that reflects the increased level of compartmentalized ferritin and blood volume in GM compared to WM (22). These results suggest that inherent variations in magnetic susceptibility may also contribute to resonance frequency shifts due to differences in levels of deoxyhemoglobin and cerebral blood volume between GM and WM, leading to enhanced contrast under radiation damping.…”
Section: Discussionmentioning
confidence: 99%
“…This effect will lead to a reduction in T2 as well as in T2*. Therefore, BOLD effects have been measured with spin echo sequences, which avoid the susceptibility artifacts inherently accompanying T2*-based techniques (39,82).…”
Section: Methodological Challenges At Higher Fieldsmentioning
confidence: 99%