In-Situ Static and Dynamic Testing and Numerical Modelling of the Dome of the Siena Cathedral (Italy)

Abstract: The chapter reports on the in-situ experimental campaign and the numerical modelling that were performed to assess the static and dynamic behaviour of the Cupola of the Siena Cathedral in Italy: an irregular polygonal masonry structure built in the 13th century and composed of two domes. The research was motivated by the failure of some of the stone-trusses which connect the two masonry domes and consists of: a) single and double flat-jack tests in the internal dome, b) dynamic vibration tests on the Cupola un… Show more