In-situ impedance and absorption coefficient measurements using a double-layer microphone array

Abstract: Acoustic impedance is typically measured using an impedance tube, which requires a material sample physically fitted to the tube. However, the impedance can vary greatly between the material mounted in the tube and the material located in a real environment, where the mounting conditions are likely to be different. Also, oblique incidence cannot be measured in an impedance tube. In this paper, we investigate the use of a double-layer microphone array for in-situ measurement of surface impedance and absorption … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
11
0
1

Year Published

2019
2019
2024
2024

Publication Types

Select...
10

Relationship

1
9

Authors

Journals

citations
Cited by 20 publications
(14 citation statements)
references
References 21 publications
(26 reference statements)
2
11
0
1
Order By: Relevance
“…However, the difference at the lower frequencies increases with increasing off-normal incidence angle. Similar results have been reported in [29]. Another relevant difference in the angle-dependent measurements is the change in the angle of sound incidence in the dip appearing at 2000 Hz for the bioboard sample.…”
Section: Discussionsupporting
confidence: 85%
“…However, the difference at the lower frequencies increases with increasing off-normal incidence angle. Similar results have been reported in [29]. Another relevant difference in the angle-dependent measurements is the change in the angle of sound incidence in the dip appearing at 2000 Hz for the bioboard sample.…”
Section: Discussionsupporting
confidence: 85%
“…Limited by the utilized transfer function tube detector of AWA6290T, only the sound absorption performance of APH-AM with normal incidence was investigated in the experiment. The sound absorption performance with oblique incidence required the modified detector [ 50 ] or the reverberation chamber method [ 51 ]. For the classical transfer function tube detector, measurement of sound absorption performance with oblique incidence required the incident tube, the sample, reflected tube with rear perfect absorbing material, and the intersection angle between incident tube and reflected tube should be adjusted to be equal to the oblique incidence angle [ 50 ].…”
Section: Resultsmentioning
confidence: 99%
“…17 Others have examined the use of ambient noise as the only source of excitation. 18 A double-layer microphone array was proposed in Hald et al 19 to estimate sound impedance and absorption of porous material samples in an anechoic room and in an ordinary room, with consistent results considering different samples sizes and incidence angles. However, most in situ measurement systems for material absorption remain, however, limited to normal incidence excitation.…”
Section: Introductionmentioning
confidence: 93%