1998
DOI: 10.1039/a806423g
|View full text |Cite
|
Sign up to set email alerts
|

In situ EPR/UV–VIS spectroelectrochemistry of polypyrrole redox cycling

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
56
1

Year Published

2003
2003
2023
2023

Publication Types

Select...
5
2

Relationship

2
5

Authors

Journals

citations
Cited by 69 publications
(57 citation statements)
references
References 2 publications
0
56
1
Order By: Relevance
“…14,98 At higher doping levels both bands shift to higher energy and two absorptions occur at 1.0 and 2.7 eV. 12 In contrast, Street et al 52 reported an absorption energy of 1.3 eV after oxidation with oxygen, Zotti et al 18 and Rapta et al 25 observed a band at 1.38 eV, and Fink et al 13 found two peaks at 1.5-2.0 eV and at 3.0 eV with electron energy loss spectroscopy at higher doping levels. Although there are significant differences in reported data and in the interpretation of experimental results, on combining polymer and oligomer data the following picture emerges: (1) since the absorption maximum of polypyrrole is close to that or slightly below that of 7P, conjugation length in PPy is likely in the range of seven to nine rings (as found also with Raman spectroscopy 99 ); (2) monocations and polarons give rise to two sub-band peaks at about 0.7-0.8 and 2.1-2.3 eV, while dications or bipolarons have a characteristic absorption in the range 1.0-1.4 eV.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…14,98 At higher doping levels both bands shift to higher energy and two absorptions occur at 1.0 and 2.7 eV. 12 In contrast, Street et al 52 reported an absorption energy of 1.3 eV after oxidation with oxygen, Zotti et al 18 and Rapta et al 25 observed a band at 1.38 eV, and Fink et al 13 found two peaks at 1.5-2.0 eV and at 3.0 eV with electron energy loss spectroscopy at higher doping levels. Although there are significant differences in reported data and in the interpretation of experimental results, on combining polymer and oligomer data the following picture emerges: (1) since the absorption maximum of polypyrrole is close to that or slightly below that of 7P, conjugation length in PPy is likely in the range of seven to nine rings (as found also with Raman spectroscopy 99 ); (2) monocations and polarons give rise to two sub-band peaks at about 0.7-0.8 and 2.1-2.3 eV, while dications or bipolarons have a characteristic absorption in the range 1.0-1.4 eV.…”
Section: Discussionmentioning
confidence: 99%
“…12,13,[16][17][18] The sub-band transitions of doped COPs were rationalized originally in terms of bipolaron formation since there is no correlation between ESR signals and conductivity. 9,[19][20][21][22] Preference for bipolarons has been questioned by some experimentalists from the start, 17,18,[23][24][25][26] but others rationalized their observations in terms of bipolarons. 13,16,22 Especially after the doping behavior of monodisperse polyenes [27][28][29] and oligothiophenes (OTs) [30][31][32][33][34][35][36][37][38][39][40][41] was investigated in solution, the bipolaron model was challenged.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…A detailed description of the spectroelectrochemical flat cell together with the electrode system and its preparation can be found elsewhere. [25,26] Measurements at 360 K were carried out in a small flat spectroelectrochemical cell for temperature-controlled experiments. [27] The tightly closed cells were transferred from the glove box into the EPR cavity (ER4104OR or ER4103TM, both Bruker, Germany) where the EPR spectra were acquired.…”
Section: Methodsmentioning
confidence: 99%
“…Similar experiments with this cell construction were successfully applied to the spectroelectrochemistry of pyrrole hexamer by using a gold micromesh electrode. [17] The gold LIGA electrodes used in this study ensure stable handling during the measurements due to their mechanical stability. The larger active and welldefined metal electrode surface of the LIGA structure results in a better electrochemical response compared to commercially available gold micromeshes, which is advantageous for detailed mechanistic studies.…”
Section: Resultsmentioning
confidence: 99%