“…When an overvoltage disturbance occurs, the resistance of this arrester will be very small so that it will provide a very fast response to drain more current to the ground [4]. A fire jump between the gaps will occur when the incoming discharge current reaches the arrester and the discharge voltage reaches the peak [9].…”
Section: Zno Surge Arrestermentioning
confidence: 99%
See 1 more Smart Citation
“…When an overvoltage disturbance occurs, the resistance of this arrester will be very small so that it will provide a very fast response to drain more current to the ground [4]. A fire jump between the gaps will occur when the incoming discharge current reaches the arrester and the discharge voltage reaches the peak [9].…”
Section: Zno Surge Arrestermentioning
confidence: 99%
“…The degradation experienced by ZnO arresters without gaps occurs gradually under operating voltage, and electrical or mechanical stress and can also be a problem with the ZnO arrester structure becoming damp [19,20]. All of these things can cause an increase in the internal leakage current, especially the resistive component of the arrester [9,21]. The aging rate of the block arrester is affected by the leakage current from the resistive component due to a pure sinusoidal voltage for the fundamental frequency component [3].…”
Section: Zno Surge Arrester Degradationmentioning
confidence: 99%
“…Leakage current is the presentation form of the comprehensive effect of complex operating conditions on power equipment, which can represent the key information of the operation status and is convenient for online real-time monitoring [1][2][3]. Leakage current includes resistive current and capacitive current [4,5], with the resistive current only accounting for about 10% of the total current. Although the total leakage current does not obviously increase, the resistive component increases a lot when the equipment fails in the early stages.…”
Section: Introductionmentioning