Improved low-cost sliding mode control of 4-leg inverter for isolated microgrid applications

Abstract: Summary Isolated microgrids including several sources of clean energy such as photovoltaic system can be considered as the auxiliary source of power generation. However, unbalanced condition is inevitable in typical microgrids due to asymmetric power generation and consumption. To supply load from different distributed generation, an interface 4‐wire power converter is essential. A 4‐leg inverter with suitable control method is a beneficial solution to support unbalanced loading condition. However, high reliab… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4

Citation Types

0
15
0

Year Published

2019
2019
2022
2022

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 16 publications
(16 citation statements)
references
References 25 publications
(46 reference statements)
0
15
0
Order By: Relevance
“…[7][8][9][10][11][12][13][14] Specific investigations reveal that the currents that circulate through the neutral conductor are predominantly characterized by zero-sequence harmonic currents, also called triplen harmonics (ie, 3 rd , 9 th , 15 th , ...). [7][8][9][10][11][12][13][14] Specific investigations reveal that the currents that circulate through the neutral conductor are predominantly characterized by zero-sequence harmonic currents, also called triplen harmonics (ie, 3 rd , 9 th , 15 th , ...).…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations
“…[7][8][9][10][11][12][13][14] Specific investigations reveal that the currents that circulate through the neutral conductor are predominantly characterized by zero-sequence harmonic currents, also called triplen harmonics (ie, 3 rd , 9 th , 15 th , ...). [7][8][9][10][11][12][13][14] Specific investigations reveal that the currents that circulate through the neutral conductor are predominantly characterized by zero-sequence harmonic currents, also called triplen harmonics (ie, 3 rd , 9 th , 15 th , ...).…”
Section: Introductionmentioning
confidence: 99%
“…Sometimes, these harmonic currents reach values higher than the fundamental component. [10][11][12][13][14][15][16][17][18] The use of electromagnetic devices has shown to be a promising alternative for the reduction of harmonic components, namely the triplen harmonics, which have a strong zero-sequence concentration. [13][14][15][16][17] In the last years, different techniques, active and passive, have been applied aiming at the elimination or reduction of the zero-sequence harmonic currents in four-wire power systems.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…33 There are several control methods used to adapt the system voltage and frequency values for islanded MGs. These control methods are divided into noncommunication-based control methods [6][7][8][9][10][11][12][13][14][15][16][17][18][19][20][21][22][23][24] and communication control methods. [25][26][27][28][29] The first one includes droop control, peer-to-peer control, hierarchical control, PI/PID control, and sliding mode control.…”
Section: Introductionmentioning
confidence: 99%
“…Generally, the control of inverter is achieved by PI, PID, and direct power control. The sliding mode control (SMC) 22,[31][32][33][34][35][36][37][38] provides the dynamic response to the nonlinear systems with the property of hysteresis. The steady-state error of the system is low compared with other controllers.…”