2019
DOI: 10.1016/j.cej.2019.05.143
|View full text |Cite
|
Sign up to set email alerts
|

Implementation of a borescopic technique in a conical spouted bed for tracking spherical and irregular particles

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
4
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 13 publications
(6 citation statements)
references
References 41 publications
0
4
0
Order By: Relevance
“…PIV technique is a very useful measurement method due its simplicity, but half-column contactors must been used. Therefore, an intrusive PTV technique was proposed by our research group in a previous study, in which it was demonstrated that it is a suitable measuring technique due to the high accuracy of the results (an error lower than 10%) [26] and flexibility of the set-up.…”
Section: Introductionmentioning
confidence: 99%
“…PIV technique is a very useful measurement method due its simplicity, but half-column contactors must been used. Therefore, an intrusive PTV technique was proposed by our research group in a previous study, in which it was demonstrated that it is a suitable measuring technique due to the high accuracy of the results (an error lower than 10%) [26] and flexibility of the set-up.…”
Section: Introductionmentioning
confidence: 99%
“…It is worth mentioning that the developed method was implemented in Python 3.6 programming language, executed on a personal computer with Linux Ubuntu operating system and AMD Ryzen 7 1700 and 8 GB of RAM. The computational processing time per 1000 frames is 120 s. To give a perspective of the importance of computational performance in digital image treatment, other similar state-of-the-art deep learning-based methods such as PIV-DCNN, LiteFlowNet-en, PIV-RAFT, and LightPIVNet take 698, 42, 26, and 36 s to process 1000 frames, respectively.…”
Section: Methodsmentioning
confidence: 99%
“…The Farneback dense optical flow estimation method 23 is used to estimate the local relative velocity which is a dimensionless quantity. The parameters used were a window size of five with four levels and three iterations.…”
Section: Relative Fluid Velocity Estimationmentioning
confidence: 99%
“…The gas flow rate to attain a u/u ms of 4 is considerable lower than in the base case (7 L min -1 instead of 10 L min -1 ) due to the lower particle size and density of the FCC catalyst. It is noteworthy that draft tubes ease the handling of solids with different sizes and densities without stability problems [71].…”
Section: Effect Of Catalyst Loadingmentioning
confidence: 99%