2022
DOI: 10.1007/s43465-022-00733-1
|View full text |Cite
|
Sign up to set email alerts
|

Implant Survival of 680 Consecutive EcoFit® Flat Single-Wedge Cementless Femoral Stems is Equivalent to the Taperloc® Total Hip Arthroplasty Series

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2023
2023
2023
2023

Publication Types

Select...
1

Relationship

1
0

Authors

Journals

citations
Cited by 1 publication
(2 citation statements)
references
References 25 publications
0
2
0
Order By: Relevance
“…The periprosthetic fracture rate of ABG-II femoral stems was further compared to the previously published results of uncemented femoral stems Zweymüller SL-PLUS and EcoFit, used in the same tertiary hospital by the same group of surgeons [ 13 , 14 ]. It turned out the ABG-II femoral stem periprosthetic fracture rate 0.52 per 100 observed component-years (i.e., 48 postoperative periprosthetic fractures after 9291 component-years) in the presented study was considerably higher than Zweymüller SL-PLUS with 0.05 per 100 observed component-years (i.e., 11 postoperative periprosthetic fractures after 23,255 component-years [ 13 ]) or EcoFit with 0.19 per 100 observed component-years (i.e., 11 postoperative periprosthetic fractures after 5851 component-years [ 14 ]) and the difference was statistically significant p < 0.01 for both comparisons.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…The periprosthetic fracture rate of ABG-II femoral stems was further compared to the previously published results of uncemented femoral stems Zweymüller SL-PLUS and EcoFit, used in the same tertiary hospital by the same group of surgeons [ 13 , 14 ]. It turned out the ABG-II femoral stem periprosthetic fracture rate 0.52 per 100 observed component-years (i.e., 48 postoperative periprosthetic fractures after 9291 component-years) in the presented study was considerably higher than Zweymüller SL-PLUS with 0.05 per 100 observed component-years (i.e., 11 postoperative periprosthetic fractures after 23,255 component-years [ 13 ]) or EcoFit with 0.19 per 100 observed component-years (i.e., 11 postoperative periprosthetic fractures after 5851 component-years [ 14 ]) and the difference was statistically significant p < 0.01 for both comparisons.…”
Section: Resultsmentioning
confidence: 99%
“…Revision rates due to periprosthetic fractures in the presented ABG-II femoral stem cohort were considerably higher from other uncemented femoral stems used in the same hospital by the same group of surgeons (University Medical Centre Ljubljana, Department of Orthopaedic Surgery) [ 13 , 14 ] in arthroplasty registries worldwide [ 16 , 17 ] or in other implant types [ 18 20 ]. The design setting of our study enabled adjustment for variability between surgeons in the multivariate analysis and clearly showed that the high ABG-II periprosthetic fracture rate was neither surgeon-dependent nor hospital-specific.…”
Section: Discussionmentioning
confidence: 99%