Impact of preanalytical storage on the measurement of erythrocyte sedimentation rate using an infrared microphotometer system (TEST1)

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
3
0

Year Published

2022
2022
2022
2022

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(3 citation statements)
references
References 3 publications
0
3
0
Order By: Relevance
“…Another study on the same analyzer showed a significant decrease of ESR values when samples were stored at room temperature for 48 h 5 . Finally, a recent stability study on ESR stability on infrared microphotometer system TEST1 analyzer during 8 h at room temperature showed that samples are unaffected at these storage conditions 25 …”
Section: Discussionmentioning
confidence: 88%
See 1 more Smart Citation
“…Another study on the same analyzer showed a significant decrease of ESR values when samples were stored at room temperature for 48 h 5 . Finally, a recent stability study on ESR stability on infrared microphotometer system TEST1 analyzer during 8 h at room temperature showed that samples are unaffected at these storage conditions 25 …”
Section: Discussionmentioning
confidence: 88%
“…5,9,13 Another study on the same analyzer showed a significant decrease of ESR values when samples were stored at room temperature for 48 h. 5 Finally, a recent stability study on ESR stability on infrared microphotometer system TEST1 analyzer during 8 h at room temperature showed that samples are unaffected at these storage conditions. 25 To the best of our knowledge, this is the first study dealing with the short-term stability of citrate and EDTA anticoagulated whole blood at room temperature on a larger sample size. It is crucial to determine whether this preanalytical factor could affect ESR values since these are conditions which most laboratories face in their routine practice.…”
Section: Resultsmentioning
confidence: 97%
“…In 2017, this method was listed by the International Council for Standardization in Haematology (ICSH) as a practical alternative to the Westergren method for ESR testing. 3 , 4 Good practice for internal quality control is an important component in the overall quality system of a Laboratory and is also the foundation for guaranteeing the accuracy of test results. 5 , 6 Applying operating calibrator and quality control for the TEST1 ESR Analyzer are both costly and long ordering period and matrix effect, 7 because the equipment is imported, although the charge for taking an ESR test is very low.…”
mentioning
confidence: 99%