2018
DOI: 10.1039/c8ra04460k
|View full text |Cite
|
Sign up to set email alerts
|

Immunomagnetic bead-based biotin-streptavidin system for highly efficient detection of aflatoxin B1 in agricultural products

Abstract: A strategy of immunomagnetic beads coupled with biotin-streptavidin system (BAS-IMB) for detecting AFB1 was suggested and applied in agricultural products.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
7
0

Year Published

2019
2019
2022
2022

Publication Types

Select...
8

Relationship

2
6

Authors

Journals

citations
Cited by 14 publications
(7 citation statements)
references
References 24 publications
0
7
0
Order By: Relevance
“…The biotinylated antibody probe and magnetic probe were prepared in order to develop the MBI method. The biotinylated antibody probe was prepared by using the carbodiimide method [ 31 , 32 ]. The anti-BBP PcAb (dialyzed for 4 h in 0.1 mol/L CBS buffer, pH 9.2) was mixed with BNHS (3.8 mg in 100 μL DMSO), then incubated at 25 °C for 6 h. After dialysis in 0.01 mol/L PBS buffer overnight at 4 °C, the prepared biotinylated antibody probe was stored in 0.01 mol/L PBS buffer containing 50% glycerol and 3% bovine serum albumin.…”
Section: Methodsmentioning
confidence: 99%
“…The biotinylated antibody probe and magnetic probe were prepared in order to develop the MBI method. The biotinylated antibody probe was prepared by using the carbodiimide method [ 31 , 32 ]. The anti-BBP PcAb (dialyzed for 4 h in 0.1 mol/L CBS buffer, pH 9.2) was mixed with BNHS (3.8 mg in 100 μL DMSO), then incubated at 25 °C for 6 h. After dialysis in 0.01 mol/L PBS buffer overnight at 4 °C, the prepared biotinylated antibody probe was stored in 0.01 mol/L PBS buffer containing 50% glycerol and 3% bovine serum albumin.…”
Section: Methodsmentioning
confidence: 99%
“…To develop a highly effective and sensitive BAS-MBI for ZEN, two immunoprobes of magnetic antigen probe and biotinylated antibody probe were prepared. Firstly, the magnetic antigen probe was prepared through the coupling of magnetic-particles and ZEN-antigen by NHS/EDC activation method [29,31,32]. Well-dispered surface carboxyl-functional group-modified magnetic-particles (50 μL) were created with sulfo-NHS (19.8 mg in 200 μL H 2 O) and EDC (10.2 mg in 200 μL H 2 O) in MES buffer (550 μL) and were activated for 30 min at 25 °C.…”
Section: Methodsmentioning
confidence: 99%
“…Magnetic bead immunoassay (MBI), a potential homogeneous assay which provides a fully reaction interface in magnetic particles as compared to the microtiter plate-based method, could be achieved with efficient magnetic separation and a convenient detection procedure [27,28]. The biotin–streptavidin system (BAS) is an ideal strategy to realize the amplification of signal and improvement of sensitivity [29]. With the help of the BAS, the labeling tracer amount of immunoassay can be significantly increased and the detection signal is more obvious, thus ensuring higher sensitivity and avoiding the use of a tracer-labeled second antibody [30].…”
Section: Introductionmentioning
confidence: 99%
“…In recent years, magnetic nanoparticles based technology with multidisciplinary and remarkable characteristics offers great possibilities for development for new analytical methodology [24–26]. Immunomagnetic beads (IMBs) due to the distinct physical and chemical properties, such as uniform diameter particles, large surface area, simplicity, superior compatibility, good sensitivity, and easy operation that can be homogenously distributed in colloidal suspension, have been widely applied in various fields, including nucleic acid extraction, peptide and protein analysis, and antibody purification [27–31]. In addition, IMBs have good biocompatibility for coupling with antibodies or small molecules and larger surface area than the flat base of a microtiter plate, which immobilizes more numbers of “active molecules” and enhances the sensitivity of the immunoassay.…”
Section: Introductionmentioning
confidence: 99%