Proceedings of the VTH International Workshop "Critical Infrastructures: Contingency Management, Intelligent, Agent-Based, Clou 2018
DOI: 10.2991/iwci-18.2018.4
|View full text |Cite
|
Sign up to set email alerts
|

Imitative Modelling of Electromagnetic Safety Conditions in Smart Power Supply Systems

Abstract: The implementation of intelligent railway power supply system requires the development of computer technologies for modeling modes and electromagnetic fields determining the conditions for electromagnetic safety. Such technologies are implemented based on the methods developed at the Irkutsk State Transport University. The formation of intelligent power supply systems will solve the following important tasks: provision of high reliability of power supply for traction of trains, as well as for non-traction and … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2019
2019
2020
2020

Publication Types

Select...
3
2

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(2 citation statements)
references
References 3 publications
(4 reference statements)
0
2
0
Order By: Relevance
“…EMS conditions are determined by the levels of EMF strengths [11][12][13][14][15][16][17][18][19][20][21], which are usually calculated at a standard height of 1.8 m [22]. To determine the strengths at the intersection points of OPL and TN, the algorithm [17] is used, which includes the phases shown in fig.…”
Section: Computer Models For Analyzing Ems Conditions At the Intersecmentioning
confidence: 99%
“…EMS conditions are determined by the levels of EMF strengths [11][12][13][14][15][16][17][18][19][20][21], which are usually calculated at a standard height of 1.8 m [22]. To determine the strengths at the intersection points of OPL and TN, the algorithm [17] is used, which includes the phases shown in fig.…”
Section: Computer Models For Analyzing Ems Conditions At the Intersecmentioning
confidence: 99%
“…This can lead to an increase in strengths and a complication of the EMF spatial structures [4]. In works [2,[15][16][17][18][19][20], a method was proposed for determining the fields of multi-wire systems, including traction net-works and power lines, based on preliminary calculation of the electrical network operating mode, which may contain mul-ti-wire lines, single-phase and three-phase transformers of various types, traction AC networks and moving traction loads. Fazonord software application [15] designed in Irkutsk State Transport university, combines possibilities for modes simulation in phase coordinates and simultaneous calculations of EMF strengths.…”
Section: Introductionmentioning
confidence: 99%