2011
DOI: 10.1002/rcm.4927
|View full text |Cite
|
Sign up to set email alerts
|

Imaging mass spectrometry in transmission geometry

Abstract: Die diastereoselektive Differenzierung der beiden Methylengruppen eines cyclischen Acetals zur Erzeugung des quartären Asymmetriezentrums C22 ist das herausragende Merkmal der hoch enantioselektiven Totalsynthese von (+)‐Lasonolid A (siehe Bild). Andere Schlüsselschritte sind die Verwendung eines Sulfon‐Sulfid‐Reagens als C3‐Baustein mit zwei latenten trans‐Olefineinheiten und eine Makrocyclisierung durch intramolekulare Horner‐Emmons‐Reaktion.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

2
128
0

Year Published

2011
2011
2014
2014

Publication Types

Select...
5
2

Relationship

2
5

Authors

Journals

citations
Cited by 61 publications
(130 citation statements)
references
References 61 publications
2
128
0
Order By: Relevance
“…Even solvent-free sample preparation, used initially with Figures S2, S3) demonstrates that a laser is not necessary to produce analyte ions from matrices used in MALDI. Lasers, however, are a beneficial means of introducing sample into the inlet by ablation because the laser beam can be focused on small areas, a requirement for high resolution imaging [55].…”
Section: Production Of Highly Charged Ionsmentioning
confidence: 99%
“…Even solvent-free sample preparation, used initially with Figures S2, S3) demonstrates that a laser is not necessary to produce analyte ions from matrices used in MALDI. Lasers, however, are a beneficial means of introducing sample into the inlet by ablation because the laser beam can be focused on small areas, a requirement for high resolution imaging [55].…”
Section: Production Of Highly Charged Ionsmentioning
confidence: 99%
“…Additionally, LSII often employs transmission geometry (TG) in which the laser is aligned 180° to the sample/orifi ce and ablates the analyte from the backside (supplementary Fig. I-C) ( 52,(64)(65)(66). This technique offers further improvements to spatial resolution and high-throughput acquisitions ( 65,66 ), as only a single laser shot is required to obtain a mass spectrum.…”
Section: Laserspray Ionization Inlet (Lsii) Is a Novel Methods (Supplementioning
confidence: 99%
“…This technique offers further improvements to spatial resolution and high-throughput acquisitions ( 65,66 ), as only a single laser shot is required to obtain a mass spectrum. This is especially important for imaging mass spectrometry, in which LSII has recently been developed by Richards et al ( 65 ) to image phospholipids and sulfatides from mouse brain tissue using solvent-free sample preparation, inlet ionization (supplementary Fig. I) at 450°C, and detection of the singly charged negative ions.…”
Section: Laserspray Ionization Inlet (Lsii) Is a Novel Methods (Supplementioning
confidence: 99%
See 2 more Smart Citations