volume 157, issue 2, P259-266 2010
DOI: 10.1016/j.combustflame.2009.04.014
View full text
|
|
Share
Wei Liu, Delin Zhu, Ning Wu, Chung K. Law

Abstract: a b s t r a c tThe ignition temperature of a liquid pool of n-heptane by heated oxidizer in a stagnation flow was experimentally determined for system pressures of 0.61-3 atm and pressure-weighted strain rates of 60-350 s À1 . The surface of the liquid pool was maintained at a fixed location through continuous replenishment. The state of ignition was brought about, and monitored, by gradually increasing the oxidizer temperature. The strain rate was determined by seeding and measuring the oxidizer flow velocit…

expand abstract