Identification and small-signal analysis of interaction modes in VSC MTDC systems

Abstract: Abstract-In this paper, a methodology is presented to identify and analyse interaction modes between converters in Voltage Source Converter Multi-Terminal High Voltage Direct Current (VSC MTDC) systems. The absence of a substantial level of energy stored in such power electronics based systems results in fast system dynamics, governed by electromagnetic phenomena. Moreover, interactions between components are largely influenced by the control parameters and in general, an a-priori identification of interaction… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
87
0

Year Published

2017
2017
2022
2022

Publication Types

Select...
4
4

Relationship

1
7

Authors

Journals

citations
Cited by 58 publications
(87 citation statements)
references
References 8 publications
0
87
0
Order By: Relevance
“…A DC voltage droop control, as expected for HVDC operation in MTDC grids [13], [14], is also included in the model. Furthermore, the adapted state-space model is linearized, and the impact of the equivalent DC-side capacitance and the droop gain on the poorly damped oscillation modes that occur with the Classical CCSC are investigated by eigenvalue analysis.…”
Section: Introductionmentioning
confidence: 99%
“…A DC voltage droop control, as expected for HVDC operation in MTDC grids [13], [14], is also included in the model. Furthermore, the adapted state-space model is linearized, and the impact of the equivalent DC-side capacitance and the droop gain on the poorly damped oscillation modes that occur with the Classical CCSC are investigated by eigenvalue analysis.…”
Section: Introductionmentioning
confidence: 99%
“…Note that for the non-conventional control structure, the first two equations in (10) are replaced by (12), as the active current takes on the task of energy regulation.…”
Section: A) Conventional Controlmentioning
confidence: 99%
“…This interaction mode identification method is proposed by [12]. With this method, the hybrid ac/dc system is divided into subsystems.…”
Section: B Participation Factor Based Interaction Analysismentioning
confidence: 99%
See 1 more Smart Citation
“…[3]), including the effect of droop controllers (e.g. [4]), and from the more practical transient stability perspective (e.g.…”
Section: Introductionmentioning
confidence: 99%