2022
DOI: 10.1186/s13017-022-00409-z
|View full text |Cite
|
Sign up to set email alerts
|

Hybrid gastroenterostomy using a lumen-apposing metal stent: a case report focusing on misdeployment and systematic review of the current literature

Abstract: Background Gastric outlet obstruction can result from several benign and malignant diseases, in particular gastric, duodenal or pancreatic tumors. Surgical gastroenterostomy and enteral endoscopic stenting have represented effective therapeutic options, although recently endoscopic ultrasound-guided gastroenterostomy using lumen-apposing metal stent (LAMS) is spreading improving the outcome of this condition. However, this procedure, although mini-invasive, is burdened with not negligible compl… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
2
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 6 publications
(2 citation statements)
references
References 39 publications
0
2
0
Order By: Relevance
“…In EUS-BD, stent misdeployment may be associated with spillage of bile and secretions into the peritoneal cavity or retroperitoneal space, resulting in peritonitis and pneumoretroperitoneum[ 90 ]. Recently Fabbri et al [ 91 ] proposed a classification of misdeployment types during EUS-guided gastroenterostomy as follows: Proximal flange misdeployment, distal flange misdeployment, stent misdeployment perforating other organs, and stent misdeployment into the peritoneum. This model considers which flange is misdeployed and the anatomical localization of the stent after misdeployment and can be supposedly adopted for all EUS-guided procedures involving the use of LAMS.…”
Section: Discussionmentioning
confidence: 99%
“…In EUS-BD, stent misdeployment may be associated with spillage of bile and secretions into the peritoneal cavity or retroperitoneal space, resulting in peritonitis and pneumoretroperitoneum[ 90 ]. Recently Fabbri et al [ 91 ] proposed a classification of misdeployment types during EUS-guided gastroenterostomy as follows: Proximal flange misdeployment, distal flange misdeployment, stent misdeployment perforating other organs, and stent misdeployment into the peritoneum. This model considers which flange is misdeployed and the anatomical localization of the stent after misdeployment and can be supposedly adopted for all EUS-guided procedures involving the use of LAMS.…”
Section: Discussionmentioning
confidence: 99%
“…An additional alternative salvage treatment in cases of SM was proposed by Fabbri et al The authors performed a laparoscopic-assisted EUS-guided gastroenterostomy [47].…”
mentioning
confidence: 99%