2015
DOI: 10.1016/j.reactfunctpolym.2015.09.004
|View full text |Cite
|
Sign up to set email alerts
|

HSA immobilized novel polymeric matrix as an alternative sorbent in hemoperfusion columns for bilirubin removal

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
11
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 32 publications
(11 citation statements)
references
References 38 publications
0
11
0
Order By: Relevance
“…They characterized the composite cryogels by various analyses and then performed the removal of bilirubin from plasma samples. They analyzed several parameters that affect the adsorption capacity of composite cryogel, including incubation time, albumin concentration, bilirubin concentration in plasma, and temperature, and found that the maximum bilirubin removal from plasma was 25.4 mg/g at 37.5 °C [58].…”
Section: Composite Cryogels As Versatile Tools For Biomedical Applmentioning
confidence: 99%
“…They characterized the composite cryogels by various analyses and then performed the removal of bilirubin from plasma samples. They analyzed several parameters that affect the adsorption capacity of composite cryogel, including incubation time, albumin concentration, bilirubin concentration in plasma, and temperature, and found that the maximum bilirubin removal from plasma was 25.4 mg/g at 37.5 °C [58].…”
Section: Composite Cryogels As Versatile Tools For Biomedical Applmentioning
confidence: 99%
“…it is one of the sensitive indexes of liver function level, with a molecular weight of 584.7 Da. [1] Bilirubin mainly exists and transports in the form of the bilirubin-albumin complex in plasma. Its primary metabolic process is completed in the liver.…”
Section: Introductionmentioning
confidence: 99%
“…Bilirubin (BR) is a metabolite of haemoglobin in ageing red blood cells. it is one of the sensitive indexes of liver function level, with a molecular weight of 584.7 Da [1] . Bilirubin mainly exists and transports in the form of the bilirubin‐albumin complex in plasma.…”
Section: Introductionmentioning
confidence: 99%
“…9 Kavoshchian et al have examined the human serum albumin (HSA) immobilized poly(2hydroxyethyl methacrylate) as an alternative sorbent in hemoperfusion columns that achieved a maximum bilirubin removal of 25.4 mg/g at 37.5 °C. 20 These adsorbents exhibited good hemocompatibility and have been applied in clinics. However, there is a challenge for improving the removal rate of bilirubin and decreasing patient costs.…”
Section: Introductionmentioning
confidence: 99%
“…For example, Timin et al modified the hybrid-silica materials with octyl, phenyl, and urea-propyl functional groups or the guanidine-containing polymers to increase the bilirubin adsorption capacity. , Jiang et al found that amino-grafted PES/PGMA (poly­(ether sulfone)/poly­(glycidyl methacrylate)) particles have shown great potential for the removal of bilirubin . Kavoshchian et al have examined the human serum albumin (HSA) immobilized poly­(2-hydroxyethyl methacrylate) as an alternative sorbent in hemoperfusion columns that achieved a maximum bilirubin removal of 25.4 mg/g at 37.5 °C . These adsorbents exhibited good hemocompatibility and have been applied in clinics.…”
Section: Introductionmentioning
confidence: 99%