HPLC–electrospray tandem mass spectrometry for simultaneous quantitation of eight plasma aminothiols: Application to studies of diabetic nephropathy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

2
57
0

Year Published

2010
2010
2015
2015

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 72 publications
(59 citation statements)
references
References 24 publications
2
57
0
Order By: Relevance
“…The integration windows for each of the scan methods are shown in Table 1, and the LODs of The absolute LODs for the thiols were in the sub-picomole range, and they were better than the LC-UV methods (11,12,33), most of the MS based detection methods (5,(34)(35)(36)(37)(38)(39), and the results via fluorescence measurement (40,41).…”
Section: Figures Of Merit For the Analytical Protocolmentioning
confidence: 99%
“…The integration windows for each of the scan methods are shown in Table 1, and the LODs of The absolute LODs for the thiols were in the sub-picomole range, and they were better than the LC-UV methods (11,12,33), most of the MS based detection methods (5,(34)(35)(36)(37)(38)(39), and the results via fluorescence measurement (40,41).…”
Section: Figures Of Merit For the Analytical Protocolmentioning
confidence: 99%
“…SAMe contents were determined by reverse phase-HPLC, as described previously (Jiang et al, 2009). The contents were quantified using an Dionex ultimate 3000 (USA) system.…”
Section: Quantification Of the Levels Of Same By Hplcmentioning
confidence: 99%
“…The concentrations of SAMe were determined using the equations of linear regression obtained from the calibration curves. Method validation including intra-day precision, inter-day precision, extraction recoveries and stabilities were analysed as described previously (Jiang et al, 2009;Krijt et al, 2009). …”
Section: Quantification Of the Levels Of Same By Hplcmentioning
confidence: 99%
“…Cellular and plasma levels of SAM and SAH correlate with each other and with total homocystein level [10]. Plasma levels of SAM and SAH are 60-90 and 20-30 nM, respectively [13], and therefore, highsensitivity methods are used for their analysis: HPLC and capillary electrophoresis (CE) with fl uorescent detection [2,12] and chloracetaldehyde derivatization as well as HPLC-MC [6,8,13]. This involves the use of sophisticated methods and/or is fraught with systematic errors due to derivatization reaction.…”
mentioning