2012
DOI: 10.1016/j.jelechem.2012.08.002
|View full text |Cite
|
Sign up to set email alerts
|

Highly sensitive and simultaneous determination of ascorbic acid and rutin at an acetylene black paste electrode coated with cetyltrimethyl ammonium bromide film

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
10
0

Year Published

2013
2013
2021
2021

Publication Types

Select...
8
1

Relationship

2
7

Authors

Journals

citations
Cited by 25 publications
(10 citation statements)
references
References 43 publications
0
10
0
Order By: Relevance
“…In addition, Several methods have been reported for simultaneous determination of mixture of these active ingredients like UV spectrophotometry [23,24], electrochemical method [25][26][27], chemiluminescence [28], capillary electrophoresis [29][30][31][32], high-performance liquid chromatography (HPLC) [33][34][35][36]and NIR FTIR [37]. The objective of this study is to develop a simple, rapid, sensitive and selective method for determination of rutin and ascorbic acid mixture in their pure forms and pharmaceutical dosage forms.…”
Section: Introductionmentioning
confidence: 99%
“…In addition, Several methods have been reported for simultaneous determination of mixture of these active ingredients like UV spectrophotometry [23,24], electrochemical method [25][26][27], chemiluminescence [28], capillary electrophoresis [29][30][31][32], high-performance liquid chromatography (HPLC) [33][34][35][36]and NIR FTIR [37]. The objective of this study is to develop a simple, rapid, sensitive and selective method for determination of rutin and ascorbic acid mixture in their pure forms and pharmaceutical dosage forms.…”
Section: Introductionmentioning
confidence: 99%
“…In addition, ascorbic acid (AA) is a chemically electroactive substance which often coexists with rutin in plants, crude drugs, pharmaceutical preparations (especially compound rutin tablets) and other biological samples. What is worse, the oxidation peak potential of AA is very close to that of rutin, indicating a poor selectivity and serious interfering effect for the rutin detection in real samples [19,20]. Therefore, the electrochemical responses of rutin in the presence of AA on the NH 2 -Fe 3 O 4 NPs-ErGO/GCE were studied.…”
Section: Resultsmentioning
confidence: 99%
“…Electrochemical methods have the virtues of low-cost apparatus, high sensitivity, wide linear range and simplicity. Due to the electroactivity of rutin, various electrodes have been modified and explored for the detection of rutin [12,13,14,15,16,17,18,19,20], and their typical analytical figures of merit for rutin analysis are compared and summarized in Table 1. In order to amplify the response signal fundamentally and improve the detection sensitivity practically, it is still important and necessary to develop new electrochemical sensors for rutin detection at the nanomolar level.…”
Section: Introductionmentioning
confidence: 99%
“…Various methods for the determination of rutin in drugs and extractants have been reviewed [3]. The simultaneous determination of rutin and ascorbic acid in pharmaceutical products has been achieved by UV spectrophotometry [4,5], voltammetry [6][7][8], and HPLC [9,10]. However, high performance liquid chromatography [11,12] and capillary electrophoresis [13,14], were the commonly used methods only for separating and determining rutin in plants.…”
Section: Introductionmentioning
confidence: 99%