2018
DOI: 10.1088/1742-6596/994/1/012016
|View full text |Cite
|
Sign up to set email alerts
|

High-throughput SANS experiment on two-detector system of YuMO spectrometer

Abstract: Abstract. Using a multidetector system on the YuMO spectrometer allows shortening the time of measurements. The quantitative comparison of the measurement time using one and twodetector mode is done. The time range for experiments was from several minutes up to 12 hours. It was shown that two-detector system shortens more than twice the time of the measurement. While making a structural investigation using advanced software the twodetector system allows to treat the data at a qualitatively new level. An exampl… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
13
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 23 publications
(14 citation statements)
references
References 36 publications
(37 reference statements)
0
13
0
Order By: Relevance
“…Our SANS experiments performed at temperatures ensuing the variation of membrane thermodynamic properties suggest for the rst time dramatic changes to the structure of membrane organization due to Aβ 25-35 incorporation. The DPPC/Aβ 25-35 membranes undergo an initial transition from EULVs (outer diameter of 800 Å) to BLSs (outer diameter of 400 Å), and both DPPC/Aβ 25-35 and DMPC/Aβ [25][26][27][28][29][30][31][32][33][34][35] membranes transition reversibly between the BLSs and SULVs (outer diameter of 200Å) during their phase transitions. Our observations are consistent with membrane damage and its subsequent reformation being caused by the separate peptides or their small oligomers.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…Our SANS experiments performed at temperatures ensuing the variation of membrane thermodynamic properties suggest for the rst time dramatic changes to the structure of membrane organization due to Aβ 25-35 incorporation. The DPPC/Aβ 25-35 membranes undergo an initial transition from EULVs (outer diameter of 800 Å) to BLSs (outer diameter of 400 Å), and both DPPC/Aβ 25-35 and DMPC/Aβ [25][26][27][28][29][30][31][32][33][34][35] membranes transition reversibly between the BLSs and SULVs (outer diameter of 200Å) during their phase transitions. Our observations are consistent with membrane damage and its subsequent reformation being caused by the separate peptides or their small oligomers.…”
Section: Discussionmentioning
confidence: 99%
“…DMPC (1 wt%) and DMPC/Aβ [25][26][27][28][29][30][31][32][33][34][35] (1 wt% total, and 3 mol% of Aβ 25-35 ) solutions were diluted in deionized water to a nal concentration of 67 µg/ml. The samples were set on carbon-coated 200 mesh copper grids with a thin layer of carbon 10 nm.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Initial SAXS data processing was performed automatically using the EDNA pipeline (Brennich et al, 2016;Incardona et al, 2009). SANS experiments were performed using aYuMO SANS spectrometer in two-detector mode (Kuklin et al, 2005) located on beamline 4 of the IBR-2 pulsed reactor at the Joint Institute for Nuclear Research, Dubna, Russia (Kuklin et al, 2018). A vanadium standard was used for absolute cross-section normalization (Kuklin et al, 2017;Ostanevich, 1988).…”
Section: Saxs and Sans Measurementsmentioning
confidence: 99%
“…SANS measurements were performed at the time-of-flight spectrometer YuMO at the IBR-2 pulsed reactor (JINR, Dubna, Russia) 34 . The beam of neutrons was formed by a set of two pinhole collimators of diameters 40 and 14 mm.…”
Section: Methodsmentioning