2018
DOI: 10.1039/c8an00719e
|View full text |Cite
|
Sign up to set email alerts
|

High sensitive and broad-range detection of cortisol in human saliva using a trap lateral flow immunoassay (trapLFI) sensor

Abstract: Cortisol, a steroid hormone, is a main biomarker of psychological stress.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
26
1

Year Published

2019
2019
2023
2023

Publication Types

Select...
7
2

Relationship

1
8

Authors

Journals

citations
Cited by 34 publications
(27 citation statements)
references
References 17 publications
0
26
1
Order By: Relevance
“…As aforementioned, LFAs are used in a variety of applications with samples that present extremely different composition and characteristics (Table 1). 27 For example, clinical samples can be whole blood, 28,29 plasma, 30,31 serum, [32][33][34] sweat, 35,36 urine, 37,38 stool, 39,40 saliva, 41,42 cerebrospinal fluid 43,44 and nasal swabs, 45,46 while food matrices could be juices, 47,48 cereals, 49,50 meat, 51,52 vegetables, 53 and environmental (mostly water and soil) samples. [54][55][56][57] Although the sample pad provides a means to control the properties of the sample solution (see the following section), some complex matrixes may require pre-treatment before an aliquot can be added into the LFA strip.…”
Section: Types Of Samples and Target Analytesmentioning
confidence: 99%
“…As aforementioned, LFAs are used in a variety of applications with samples that present extremely different composition and characteristics (Table 1). 27 For example, clinical samples can be whole blood, 28,29 plasma, 30,31 serum, [32][33][34] sweat, 35,36 urine, 37,38 stool, 39,40 saliva, 41,42 cerebrospinal fluid 43,44 and nasal swabs, 45,46 while food matrices could be juices, 47,48 cereals, 49,50 meat, 51,52 vegetables, 53 and environmental (mostly water and soil) samples. [54][55][56][57] Although the sample pad provides a means to control the properties of the sample solution (see the following section), some complex matrixes may require pre-treatment before an aliquot can be added into the LFA strip.…”
Section: Types Of Samples and Target Analytesmentioning
confidence: 99%
“…By tuning the concentration of cortisol-BSA conjugates in the deletion zone, and applying a ratiometric imaging method, the authors reported a 30-fold improvement over a conventional cortisol LFA. 75 Limitations. The reaction/transport category is home to efforts that use porous materials to automate new reaction schemes with unconventional transport dynamics.…”
Section: Reaction/transportmentioning
confidence: 99%
“…Several examples were reported based on the use of chromogenic substrates for enhancing colorimetric-based LFIAs [ 52 , 53 ]. Competitive LFIAs for multiplexed analysis of carbaryl and endosulfan using AuNPs and HRP as labels were developed by Zhang et al [ 54 ] to compare the performances obtained with the different systems.…”
Section: Enzyme-labeled Conjugates In Lfiamentioning
confidence: 99%
“…Using this platform, the HRP color signals increase in the detection zone and decrease in the deletion zone depending on the concentration of the target analyte. The ratio of signals from deletion and detection zones allowed to quantify cortisol in a wide concentration range (0.01–100 ng mL −1 ) with high detection sensitivity (9.9 pg mL −1 ) [ 52 ].…”
Section: Enzyme-labeled Conjugates In Lfiamentioning
confidence: 99%