Cochrane Database of Systematic Reviews 2011
DOI: 10.1002/14651858.cd006405.pub2
|Get access via publisher |Summarize |Cite
|
Sign up to set email alerts

High flow nasal cannula for respiratory support in preterm infants

Abstract: There is insufficient evidence to establish the safety or effectiveness of HFNC as a form of respiratory support in preterm infants. When used following extubation, HFNC may be associated with a higher rate of reintubation than nasal CPAP. Further adequately powered randomised controlled trials should be undertaken in preterm infants comparing HFNC with nasal CPAP and with other means of respiratory support; or of support following extubation. These trials should measure clinically important outcomes.

Search citation statements

Order By: Relevance

Paper Sections

Select...
132
37
32
5

Citation Types

6
203
1
5

Year Published

Range
2010
2010
2025
2025

Publication Types

Select...
168
11
4
1

Relationship

0
184

Authors

Journals

citations

Cited by 184 publications

(215 citation statements)
references

References 27 publications

6
203
1
5
Order By: Relevance
How this paper cites the one you are viewing
“…The confirmation of this result in the sensitivity analysis indicated the robustness of this finding. These data are in contrast with those obtained from meta-analyses of HFNC initiated after extubation, which have consistently shown that the efficacy is similar to NCPAP (12,13).…”
Section: Summary Of Main Results and Interpretation
contrasting