2016
DOI: 10.1016/j.enconman.2016.08.013
|View full text |Cite
|
Sign up to set email alerts
|

Heat transfer measurement in a three-phase spray column direct contact heat exchanger for utilisation in energy recovery from low-grade sources

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
8
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 24 publications
(8 citation statements)
references
References 30 publications
0
8
0
Order By: Relevance
“…For the purpose of verifying and validating the CFD model, it was decided to rely on the experimental results published in Baqir et al (Baqir, Mahood, Hameed, & Campbell, 2016). In this section, an overview of the experimental setup is provided.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…For the purpose of verifying and validating the CFD model, it was decided to rely on the experimental results published in Baqir et al (Baqir, Mahood, Hameed, & Campbell, 2016). In this section, an overview of the experimental setup is provided.…”
Section: Methodsmentioning
confidence: 99%
“…In this section, an overview of the experimental setup is provided. For further details, see (Baqir, Mahood, Hameed, & Campbell, 2016) and (Baqir A. M., 2016).…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Considering the main purpose of HEF is to enhance the in-cylinder heat transfer, HEF with high thermal diffusion and heat capacity, while having low toxicity, is desirable for the application. Liquid-gas direct-contact heat and mass transfer processes can be found in numerous industrial applications such as water desalination by freezing, geothermal power energy production, crystallisation, waste heat recovery, energy storage systems, solar power energy and emergency cooling of chemical and nuclear reactors [14][15][16][17][18]. Due to vastly different geometries and potentially highly turbulent flow fields (as in the LN 2 engine), numerical models of direct contact heat exchangers in the literature [19][20][21][22] were applicable only to simplified conditions, and very limited quantitative experimental results were available for their validation [20].…”
Section: Introductionmentioning
confidence: 99%
“…It has been reported that the DCHE-based ORC system allows better exploitation of low-grade heat than existing ORC systems. 19,20 The thermodynamic performance of the DCHE-based ORC system is strongly relied on the bubbles mixing and heat transfer processes. However, a greatly coupled association with each other exists in the two physical processes.…”
Section: Introductionmentioning
confidence: 99%